Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › AIRBAG SYSTEM

DTC    B1166/88    Open in Curtain Shield Squib LH Circuit

for Preparation Click here


DESCRIPTION

The curtain shield squib LH circuit consists of the center airbag sensor assembly and the curtain shield airbag assembly LH.
The circuit instructs the SRS to deploy when deployment conditions are met.
DTC B1166/88 is recorded when an open circuit is detected in the curtain shield squib LH circuit.

DTC No.
DTC Detecting Condition
Trouble Area
B1166/88
  1. Open circuit in ICL+ wire harness or ICL- wire harness of curtain shield squib LH
  2. Curtain shield squib LH malfunction
  3. Center airbag sensor assembly malfunction
  1. Curtain shield airbag assembly LH (Curtain shield squib LH)
  2. Center airbag sensor assembly
  3. Floor wire

WIRING DIAGRAM

Click here.

INSPECTION PROCEDURE

HINT:
  1. Perform the simulation method by selecting the "check mode" (signal check) with the Techstream (Click here).
  2. After selecting the "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).

1.CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (CURTAIN SHIELD SQUIB LH)


    C111684E03
  1. Turn the ignition switch to the LOCK position.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the connectors from the curtain shield airbag assembly LH.

  1. Connect SST (resistance 2.1 Ω) to the floor wire.

    CAUTION:
    Never connect a tester to the curtain shield airbag assembly LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    Do not forcibly insert SST into the terminals of the connector when connecting.
    Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Clear the DTCs stored in memory (Click here).

  1. Turn the ignition switch to the LOCK position.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Check the DTCs (Click here).

    OK:
    DTC B1166/88 is not output.

    HINT:
    Codes other than DTC B1166/88 may be output at this time, but they are not related to this check.



NG
Go to step 2
OK

REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY LH 

2.CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH CIRCUIT)


    C111682E03
  1. Turn the ignition switch to the LOCK position.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect SST (resistance 2.1 Ω) from the floor wire.

  1. Disconnect the connector from the center airbag sensor assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    Condition
    Specified condition
    C14-1 (ICL+) -
    C14-2 (ICL-)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE FLOOR WIRE
OK


3.CHECK CENTER AIRBAG SENSOR ASSEMBLY


    C111685E01
  1. Connect the connectors to the curtain shield airbag assembly LH and the center airbag sensor assembly.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Clear the DTCs stored in memory (Click here).

  1. Turn the ignition switch to the LOCK position.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Check the DTCs (Click here).

    OK:
    DTC B1166/88 is not output.

    HINT:
    Codes other than DTC B1166/88 may be output at this time, but they are not related to this check.



NG
REPLACE CENTER AIRBAG SENSOR ASSEMBLY
OK

USE SIMULATION METHOD TO CHECK