Home › BODY ELECTRICAL › PARK ASSIST / MONITORING › INTUITIVE PARKING ASSIST SYSTEM

INTUITIVE PARKING ASSIST SYSTEM > Back Sonar Sensor RH Circuit

for Preparation Click here


DESCRIPTION

An ultrasonic sensor consists of a sensor portion that transmits and receives ultrasonic waves and a pre-amplifier that amplifies them. The ultrasonic sensor outputs the ultrasonic waves and sends the received signals to the clearance warning ECU.

WIRING DIAGRAM


E110859E08


INSPECTION PROCEDURE

1.INSPECT NO. 2 ULTRASONIC SENSOR


    E124037E01
  1. Remove the No. 2 ultrasonic sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    Condition
    Specified condition
    1 - 2
    Always
    8 to 12 kΩ



NG
REPLACE NO. 2 ULTRASONIC SENSOR
OK


2.CHECK HARNESS AND CONNECTOR (CLEARANCE WARNING ECU - NO. 2 ULTRASONIC SENSOR)


    E124033E05
  1. Disconnect the C9 connector from the clearance warning ECU.



    I041776E08
  1. Disconnect the U5 connector from the No. 2 ultrasonic sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    Condition
    Specified condition
    S5 - S
    Always
    Below 1 Ω
    E2 - E
    Always
    Below 1 Ω
    S5 - Body ground
    Always
    10 kΩ or higher
    E2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE