Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Entire Combination Meter does not Operate

for Preparation Click here


DESCRIPTION

This is the power source circuit to operate the combination meter assembly.

WIRING DIAGRAM


E143792E01


INSPECTION PROCEDURE

1.INSPECT COMBINATION METER ASSEMBLY


    E118053E01
  1. Disconnect the C10 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    C10-30 (ES) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    C10-32 (IG+) - Body ground
    Turn the ignition switch to the ON position
    10 to 14 V
    C10-12 (+B) - Body ground
    Always
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY