Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Engine Coolant Temperature Receiver Gauge Malfunction

for Preparation Click here


DESCRIPTION

The meter CPU receives engine coolant temperature signals from the ECM via the multiplex communication lines. The meter CPU displays engine coolant temperature that is calculated based on the data received from the ECM.

WIRING DIAGRAM


E118070E07


INSPECTION PROCEDURE

HINT:
If there is an open or short in the engine coolant temperature sensor circuit, the ECM will store the DTCs. Perform troubleshooting of the "SFI System" (Click here).

1.CHECK MULTIPLEX COMMUNICATION SYSTEM
  1. Check if the MULTIPLEX communication DTC is output (Click here).

    Result:

    Result
    Proceed to
    DTC is not output
    A
    DTC is output
    B



NG
REPAIR CIRCUITS INDICATED BY OUTPUT DTCS
OK


2.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Enter the following menus: Body Electrical / Main Body / Active Test.

  1. Check the operation by referring to the values in the table below.

    Combination Meter: 
    Tester Display
    Test Part
    Test Details
    Diagnostic Note
    Water Temperature Meter Operation
    Engine coolant temperature receiver gauge
    LOW, NORMAL, HI
    -

    OK:
    Needle indication is normal.



NG
REPLACE COMBINATION METER ASSEMBLY
OK


3.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List.

  1. Check the values by referring to the values in the table below.

    Engine and ECT: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Coolant Temp
    Engine coolant temp: -40°C (-40°F) to 140°C (284°F)
    After warming up: 80 to 95°C (176 to 203°F)
    -



NG
GO TO SFI SYSTEM
OK


4.REPLACE COMBINATION METER ASSEMBLY

OK:
The operation of the combination meter assembly returns to normal.



NG
REPLACE ECM
OK

END