DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0778 | ECM checks for an open or short circuit in shift solenoid valves SL2 (1-trip detection logic) Hybrid IC for solenoid indicates fail. |
|
| Related DTCs | P0778: Shift solenoid valve SL2/Range check |
| Required sensors/Components | Shift solenoid valve SL2 |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or more |
| Ignition switch | ON |
| Starter | OFF |
| CPU commanded duty ratio to SL2 | 19% or more |
| Solenoid status from IC | Fail (Open or short) |
| Output signal duty | Less than 100% |

| 1.INSPECT TRANSMISSION WIRE (SL2) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 5 (SL2+) - 12 (SL2-) | 5.0 to 5.6 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 5 (SL2+) - Body ground | 10 kΩ or higher |
| 12 (SL2-) - Body ground | ↑ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transaxle.
Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| E10-15 (SL2+) - E10-14 (SL2-) | 5.0 to 5.6 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E10-15 (SL2+) - Body ground | 10 kΩ or higher |
| E10-14 (SL2-) - Body ground |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 1 - 2 | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | ||
| ||