DTC P2769 Torque Converter Clutch Solenoid Circuit Low (Shift Solenoid Valve DSL) |
DTC P2770 Torque Converter Clutch Solenoid Circuit High (Shift Solenoid Valve DSL) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2769 | ECM detects short in solenoid valve DSL circuit (0.1 sec.) when solenoid valve DSL is operated (2-trip detection logic) |
|
| P2770 | ECM detects open in solenoid valve DSL circuit (0.1 sec.) when solenoid valve DSL is not operated (2-trip detection logic) |
|
| Related DTCs | P2769: Shift solenoid valve DSL/Range check (Low resistance) P2770: Shift solenoid valve DSL/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve DSL |
| Frequency of operation | Continuous |
| Duration | 0.064 sec. or more |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve DSL | ON |
| Solenoid current cut status | Not cut |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve DSL | ON |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Shift solenoid valve DSL resistance | 8 Ω or less |
| Shift solenoid valve DSL resistance | 100 kΩ or more |
| Shift solenoid valve DSL | Resistance: 11 to 13 Ω at 20°C (68°F) |

| 1.INSPECT TRANSMISSION WIRE (DSL) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 10 (DSL) - Body ground | 11 to 13 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| E10-11 (DSL) - Body ground | 11 to 13 Ω |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE DSL |
![]() |
Remove the shift solenoid valve DSL.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| Solenoid Connector (DSL) - Solenoid Body (DSL) | 11 to 13 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
|
| ||||
| OK | ||
| ||