Home › BODY ELECTRICAL › PARK ASSIST / MONITORING › NO. 2 ULTRASONIC SENSOR

NO. 2 ULTRASONIC SENSOR > INSPECTION

for Preparation Click here



1. INSPECT NO.2 ULTRASONIC SENSOR


    E124037E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    Condition
    Specified condition
    1 - 2
    Always
    8 to 12 kΩ

    If the result is not as specified, replace No.2 ultrasonic sensor.