Home
›
BODY ELECTRICAL
›
PARK ASSIST / MONITORING
›
NO. 2 ULTRASONIC SENSOR
NO. 2 ULTRASONIC SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT NO.2 ULTRASONIC SENSOR
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester connection
Condition
Specified condition
1 - 2
Always
8 to 12 kΩ
If the result is not as specified, replace No.2 ultrasonic sensor.