DTC B1419/19 Rear Room Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1419/19 | Rear room temperature sensor circuit (Open or short) |
|

| 1.READ VALUE USING TECHSTREAM |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position and turn Techstream on.
Select the item below in the Data List, and read the display on Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temp Sensor (Rear) | Rear room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F) | Actual cabin temperature is displayed | - |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT REAR A/C ROOM TEMPERATURE SENSOR |
![]() |
Remove the rear A/C room temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| R23-1 - R23-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| R23-1 - R23-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| R23-1 - R23-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| R23-1 - R23-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| R23-1 - R23-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| R23-1 - R23-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| R23-1 - R23-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| R23-1 - R23-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| R23-1 - R23-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| R23-1 - R23-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| R23-1 - R23-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (REAR A/C ROOM TEMPERATURE SENSOR - A/C AMPLIFIER) |
![]() |
Disconnect the connector from the A/C amplifier.
![]() |
Disconnect the connector from the rear A/C room temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A10-18 (TR) - R23-1 | Always | Below 1 Ω |
| A10-14 (SGND) - R23-2 | Always | Below 1 Ω |
| A10-18 (TR) - Body ground | Always | 10 kΩ or higher |
| A10-14 (SGND) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||