POWER WINDOW CONTROL SYSTEM (w/ Jam Protection Function) > Remote Up / Down Function does not Operate |

| 1.CHECK POWER WINDOW LOCK SWITCH |
![]() |
Push the window lock switch OFF (normal) and check that the remote UP/DOWN function operates.
|
| ||||
| NG | |
| 2.CHECK MANUAL UP/DOWN FUNCTION |
Check that the passenger side door window and slide door windows can be operated via each regulator switch.
|
| ||||
| OK | |
| 3.INSPECT POWER WINDOW MASTER SWITCH |
![]() |
Remove the master switch.
Check the resistance between the terminals of the master switch when each switch is operated, as shown in the table below.
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 15, 6 - 13 | Below 1 Ω |
| OFF | 1 - 13 - 15 | ||
| DOWN | 1 - 13, 6 - 15 | ||
| ON (Lock) | UP | 6 - 13 | |
| OFF | 13 - 15 | ||
| DOWN | 6 - 15 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 10, 6 - 12 | Below 1 Ω |
| OFF | 1 - 10 - 12 | ||
| DOWN | 1 - 12, 6 - 10 | ||
| ON (Lock) | UP | 6 - 12 | |
| OFF | 10 - 12 | ||
| DOWN | 6 - 10 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 16, 6 - 18 | Below 1 Ω |
| OFF | 1 - 16 - 18 | ||
| DOWN | 1 - 18, 6 - 16 | ||
| ON (Lock) | UP | 6 - 18 | |
| OFF | 16 - 18 | ||
| DOWN | 6 - 16 |
|
| ||||
| OK | ||
| ||