POWER WINDOW MASTER SWITCH > INSPECTION |
| 1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/ Jam Protection Function) |
![]() |
Check the resistance between the terminals of the switch when the switch is operated.
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| - | UP | 1 - 9, 4 - 7 | Below 1 Ω |
| OFF | 1 - 4 - 9 | ||
| DOWN | 1 - 4, 7 - 9 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 15, 6 - 13 | Below 1 Ω |
| OFF | 1 - 13 - 15 | ||
| DOWN | 1 - 13, 6 - 15 | ||
| ON (Lock) | UP | 6 - 13 | Below 1 Ω |
| OFF | 13 - 15 | ||
| DOWN | 6 - 15 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 10, 6 - 12 | Below 1 Ω |
| OFF | 1 - 10 - 12 | ||
| DOWN | 1 - 12, 6 - 10 | ||
| ON (Lock) | UP | 6 - 12 | Below 1 Ω |
| OFF | 10 - 12 | ||
| DOWN | 6 - 10 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 16, 6 - 18 | Below 1 Ω |
| OFF | 1 - 16 - 18 | ||
| DOWN | 1 - 18, 6 - 16 | ||
| ON (Lock) | UP | 6 - 18 | Below 1 Ω |
| OFF | 16 - 18 | ||
| DOWN | 6 - 16 |
| 2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/o Jam Protection Function) |
![]() |
Check the resistance between the terminals of the switch when the switch is operated.
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| - | UP | 1 - 9, 4 - 6 | Below 1 Ω |
| OFF | 1 - 4 - 9 | ||
| DOWN | 1 - 4, 6 - 9 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 15, 6 - 18 | Below 1 Ω |
| OFF | 1 - 15 - 18 | ||
| DOWN | 1 - 18, 6 - 15 | ||
| ON (Lock) | UP | 6 - 18 | Below 1 Ω |
| OFF | 15 - 18 | ||
| DOWN | 6 - 15 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 13, 6 - 12 | Below 1 Ω |
| OFF | 1 - 12 - 13 | ||
| DOWN | 1 - 12, 6 - 13 | ||
| ON (Lock) | UP | 6 - 12 | Below 1 Ω |
| OFF | 12 - 13 | ||
| DOWN | 6 - 13 |
| Window Lock Switch | Power Window Switch | Terminal No. | Specified Condition |
| OFF (Normal) | UP | 1 - 16, 6 - 10 | Below 1 Ω |
| OFF | 1 - 10 - 16 | ||
| DOWN | 1 - 10, 6 - 16 | ||
| ON (Lock) | UP | 6 - 10 | Below 1 Ω |
| OFF | 10 - 16 | ||
| DOWN | 6 - 16 |