C1241/41
| When any of the following is detected:
- At a vehicle speed of 3 km/h (2mph) or more, the IG1 terminal voltage is 9.5 V or less for 10 sec. or more.
- With the IG1 terminal voltage 9.5 V or less, the vehicle speed sensor power supply decreases for 60 sec. or more.
- When the solenoid relay remains ON and the IG1 terminal voltage is 9.5 V or less, the relay contact is open for 0.2 sec. or more.
- While the motor fail safe relay is ON after motor relay ON, the IG1 terminal voltage is 9.5 V or less and the actuator pump drive motor is OFF for 0.1 sec. or more.
| - Battery
- Charging system
- Power source circuit
|