Home › COMMUNICATION SYSTEM › MULTIPLEX COMMUNICATION › MULTIPLEX COMMUNICATION SYSTEM

DTC    B1271    Combination Meter ECU Communication Stop

for Preparation Click here


DESCRIPTION

DTC B1271 is output when communication between the combination meter and the multiplex network gateway ECU stops for more than 10 seconds.

DTC No.
DTC Detection Condition
Trouble Area
B1271
Combination meter communication stops
  1. Combination meter
  2. Wire harness

WIRING DIAGRAM


C160428E03


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY)


    C160413E03
  1. Disconnect the C10 connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    C10-32 - Body ground
    Ignition switch: ON
    11 to 14 V
    C10-12 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - GROUND)


    C160413E04
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    C10-30 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK COMMUNICATION LINE


    C160733E01
  1. Disconnect the A9 and G4 connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    C10-29 - G4-3 (MPD1), G4-12 (MPD2)
    Always
    Below 1 Ω
    C10-28 - A9-2 (MPX+) (*1), A9-4 (MPX+) (*2)
    Always
    Below 1 Ω

    HINT:
    *1: for Automatic A/C
    *2: for Manual A/C

    Result:
    Result
    Proceed to
    Both are OK
    A
    One is OK
    B
    Both are NG
    C



B
REPAIR OR REPLACE HARNESS OR CONNECTOR AND COMBINATION METER

C
REPAIR OR REPLACE HARNESS OR CONNECTOR
A

REPLACE COMBINATION METER