Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > ACTUATOR CHECK

for Preparation Click here



ACTUATOR CHECK


    I035391
  1. After entering the DTC check mode (Sensor Check Mode), press the R/F switch.

  2. As each damper, motor and relay automatically operate actuator check at 1-second intervals from step No. 1 to No. 10 continuously, check the temperature and air flow visually and by hand.
    If the slower display is desired, press the DEF switch and change it to step operation. Each time the DEF switch is pressed, the display changes by 1 step.

    HINT:
    1. Codes are displayed from smaller to larger numbers in order.
    2. To cancel the check mode, press the OFF switch.


    Step No.
    Display code
    Conditions
    Fr. Blower level
    Fr. Air flow vent
    Air inlet damper
    Magnetic clutch
    Fr. Driver, passenger side air mix damper
    Rr. Blower level
    Rr. Air flow vent
    Rr. Air mix damper
    1
    0
    0
    FACE
    FRESH
    OFF
    "COOL" side
    (Full closed)
    0
    FACE1
    "COOL" side
    (Full closed)
    2
    1
    1
    FACE
    FRESH
    OFF
    "COOL" side
    (Full closed)
    1
    FACE1
    "COOL" side
    (Full closed)
    3
    2
    16
    FACE
    FRESH
    ON
    "COOL" side
    (Full closed)
    10
    FACE1
    "COOL" / "HOT"
    (40% open)
    4
    3
    16
    FACE
    FRESH / RECIRCULATION
    ON
    "COOL" side
    (Full closed)
    10
    FACE2
    "COOL" / "HOT"
    (40% open)
    5
    4
    16
    FACE
    RECIRCULATION
    ON
    "COOL" / "HOT"
    (50% open)
    10
    B/L
    "COOL" / "HOT"
    (40% open)
    6
    5
    16
    B/L
    RECIRCULATION
    ON
    "COOL" / "HOT"
    (50% open)
    10
    B/L
    "COOL" / "HOT"
    (60% open)
    7
    6
    16
    FOOT
    RECIRCULATION
    ON
    "HOT" side
    (Full open)
    10
    B/L
    "COOL" / "HOT"
    (60% open)
    8
    7
    16
    FOOT
    RECIRCULATION
    ON
    "HOT" side
    (Full open)
    10
    FOOT
    "COOL" / "HOT"
    (60% open)
    9
    8
    16
    FOOT / DEF.
    RECIRCULATION
    ON
    "HOT" side
    (Full open)
    10
    FOOT
    "COOL" / "HOT"
    (86.5% open)
    10
    9
    31
    DEF.
    RECIRCULATION
    ON
    "HOT" side
    (Full open)
    31
    FOOT
    "COOL" / "HOT"
    (86.5% open)