AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position.
From the display on the tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F) | Actual cabin temperature | - |
| Ambient Temp Sensor | Ambient temperature sensor / min.: -23.3°C (-9.94°F), max.: 65.95°C (150.71°F) | Actual ambient temperature | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / min.: -30.8°C (-23.44°F), max.: 50.8°C (123.44°F) | - | - |
| Evaporator Temp Sensor | Evaporator temperature sensor / min.: -29.7°C (-21.46°F), max.: 59.55°C (139.19°F) | Actual evaporator temperature | - |
| Solar Sensor (D Side) | Solar sensor (D side) / min.: 0, max.: 255 | Changes depending on brightness (D side) | - |
| Solar Sensor (P Side) | Solar sensor (P side) / min.: 0, max.: 255 | Changes depending on brightness (P side) | - |
| Engine Coolant Temp | Engine coolant temperature / min.: 1.3°C (34.34°F), max.: 90.55°C (194.99°F) | Actual engine coolant temperature | - |
| Set Temperature (D Side) | Set temperature (D side) / min.: 0, max. 255 | Actual set temperature (D side) | - |
| Set Temperature (P Side) | Set temperature (P side) / min.: 0, max. 255 | Actual set temperature (P side) | - |
| Air Mix Damper Position (D) | Air mix damper position (D side) / min.: -14%, max.: 113.5% | Changes depending on the set temperature (D side) | - |
| Air Mix Damper Position (P) | Air mix damper position (P side) / min.: -14%, max.: 113.5% | Changes depending on the set temperature (P side) | - |
| Air Inlet Damper Position | Air inlet damper position / min.: -14%, max.: 113.5% | Changes depending on air inlet damper position | - |
| Air Outlet Damper Position | Air outlet damper position / min.: -14%, max.: 113.5% | Changes depending on air outlet damper position | - |
| Air Mix Damper Target (D) | Air mix damper target position (D side) / min.: -14%, max.: 113.5% | Changes depending on the set temperature (D side) | - |
| Air Mix Damper Target (P) | Air mix damper target position (P side) / min.: -14%, max.: 113.5% | Changes depending on the set temperature (P side) | - |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14%, max.: 113.5% | Changes depending on air inlet damper position | - |
| Air Outlet Damper Target | Air outlet damper target position / min.: -14%, max.: 113.5% | Changes depending on air outlet damper position | - |
| Blower Motor Speed Level | Blower motor speed level / min.: Level 0, max.: Level 31 | Changes depending on blower level | - |
| Room Temp Sensor (Rear) | Room temperature sensor (Rear) / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F) | Actual cabin temperature (Rear) | - |
| Ambient Temp Sens (Rear) | Rr. EVAP temperature sensor (Rear) / min.: -29.7°C (-21.46°F), max.: 59.55°C (139.19°F) | Actual evaporator temperature (Rear) | - |
| Set Temperature (Rear) | Set temperature (Rear) / min.: 0, max. 255 | Actual set temperature | - |
| Air Mix Damper (Rear) | Air mix damper position (Rear) / min.: -14%, max.: 113.5% | Changes depending on the set temperature (Rear) | - |
| Air Outlet Damper (Rear) | Air outlet mode damper position (Rear) / min.: -14%, max.: 113.5% | Changes depending on air outlet damper position (Rear) | - |
| Air Mix Damper Targ (Rear) | Air mix damper target position (Rear) / min.: -14%, max.: 113.5% | Changes depending on the set temperature (Rear) | - |
| Air Out Damper Targ (Rear) | Air outlet damper target position (Rear) / min.: -14%, max.: 113.5% | Changes depending on air outlet damper position (Rear) | - |
| Blower Motor Level (Rear) | Blower motor speed level (Rear) / min.: Level 0, max: Level 31 | Changes depending on blower level (Rear) | - |
| Shift Set Temperature | Shift set temperature | Changes depending on shift set temperature *1 | - |
| Air Inlet Mode | Air inlet mode | Changes depending on air inlet mode *1 | - |
| Compressor Mode | Compressor mode | Changes depending on compressor mode *1 | - |
| Compressor/DEF Mode | Compressor/DEF operation mode | Changes depending on compressor/DEF operation mode *1 | - |
| Foot/DEF Auto Mode | Foot/DEF auto mode | Changes depending on Foot/DEF auto mode *1 | - |
| Foot/DEF Auto Blow Up | Foot/DEF automatic blow up function | Changes depending on Foot/DEF automatic blow up function *1 | - |
| Number of Trouble Codes | Number of Trouble Codes / min.: 0, max.: 255 | - | - |
| ACTIVE TEST |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position.
From the display on the tester, read the "Active Test".
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | min.: Level 0, max.: Level 31 | - |
| Air Mix Damper (D Side) | Air mix damper (D side) | min.: -14%, max: 113.5% | - |
| Air Mix Damper (P Side) | Air mix damper (P side) | min.: -14%, max: 113.5% | - |
| Air Outlet Damper Position (D Side) | Air outlet damper position (D side) | min.: -14%, max: 113.5% | - |
| Air Inlet Damper Position (Linear) | Air inlet damper position (linear) | min.: -14%, max: 113.5% | - |
| Blower Motor (Rear) | Blower motor (Rear) | OFF, LO, HI | - |
| Air Mix Damper (Rear) | Air mix damper (Rear) | min.: -14%, max: 113.5% | - |
| Air Outlet Damper Position (Rear) | Air outlet damper position (Rear) | min.: -14%, max: 113.5% | - |
| Magnetic Clutch Relay | Magnetic clutch relay | OFF, ON | - |