Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

HINT:
Using Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

  1. Connect Techstream to the DLC3.

  2. Turn the ignition switch to the ON position.

  3. From the display on the tester, read the "Data List".

    Air Conditioner / Data List: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F)
    Actual cabin temperature
    -
    Ambient Temp Sensor
    Ambient temperature sensor / min.: -23.3°C (-9.94°F), max.: 65.95°C (150.71°F)
    Actual ambient temperature
    -
    Adjusted Ambient Temp
    Adjusted ambient temperature / min.: -30.8°C (-23.44°F), max.: 50.8°C (123.44°F)
    -
    -
    Evaporator Temp Sensor
    Evaporator temperature sensor / min.: -29.7°C (-21.46°F), max.: 59.55°C (139.19°F)
    Actual evaporator temperature
    -
    Solar Sensor (D Side)
    Solar sensor (D side) / min.: 0, max.: 255
    Changes depending on brightness (D side)
    -
    Solar Sensor (P Side)
    Solar sensor (P side) / min.: 0, max.: 255
    Changes depending on brightness (P side)
    -
    Engine Coolant Temp
    Engine coolant temperature / min.: 1.3°C (34.34°F), max.: 90.55°C (194.99°F)
    Actual engine coolant temperature
    -
    Set Temperature (D Side)
    Set temperature (D side) / min.: 0, max. 255
    Actual set temperature (D side)
    -
    Set Temperature (P Side)
    Set temperature (P side) / min.: 0, max. 255
    Actual set temperature (P side)
    -
    Air Mix Damper Position (D)
    Air mix damper position (D side) / min.: -14%, max.: 113.5%
    Changes depending on the set temperature (D side)
    -
    Air Mix Damper Position (P)
    Air mix damper position (P side) / min.: -14%, max.: 113.5%
    Changes depending on the set temperature (P side)
    -
    Air Inlet Damper Position
    Air inlet damper position / min.: -14%, max.: 113.5%
    Changes depending on air inlet damper position
    -
    Air Outlet Damper Position
    Air outlet damper position / min.: -14%, max.: 113.5%
    Changes depending on air outlet damper position
    -
    Air Mix Damper Target (D)
    Air mix damper target position (D side) / min.: -14%, max.: 113.5%
    Changes depending on the set temperature (D side)
    -
    Air Mix Damper Target (P)
    Air mix damper target position (P side) / min.: -14%, max.: 113.5%
    Changes depending on the set temperature (P side)
    -
    Air Inlet Damper Target
    Air inlet damper target position / min.: -14%, max.: 113.5%
    Changes depending on air inlet damper position
    -
    Air Outlet Damper Target
    Air outlet damper target position / min.: -14%, max.: 113.5%
    Changes depending on air outlet damper position
    -
    Blower Motor Speed Level
    Blower motor speed level / min.: Level 0, max.: Level 31
    Changes depending on blower level
    -
    Room Temp Sensor (Rear)
    Room temperature sensor (Rear) / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F)
    Actual cabin temperature (Rear)
    -
    Ambient Temp Sens (Rear)
    Rr. EVAP temperature sensor (Rear) / min.: -29.7°C (-21.46°F), max.: 59.55°C (139.19°F)
    Actual evaporator temperature (Rear)
    -
    Set Temperature (Rear)
    Set temperature (Rear) / min.: 0, max. 255
    Actual set temperature
    -
    Air Mix Damper (Rear)
    Air mix damper position (Rear) / min.: -14%, max.: 113.5%
    Changes depending on the set temperature (Rear)
    -
    Air Outlet Damper (Rear)
    Air outlet mode damper position (Rear) / min.: -14%, max.: 113.5%
    Changes depending on air outlet damper position (Rear)
    -
    Air Mix Damper Targ (Rear)
    Air mix damper target position (Rear) / min.: -14%, max.: 113.5%
    Changes depending on the set temperature (Rear)
    -
    Air Out Damper Targ (Rear)
    Air outlet damper target position (Rear) / min.: -14%, max.: 113.5%
    Changes depending on air outlet damper position (Rear)
    -
    Blower Motor Level (Rear)
    Blower motor speed level (Rear) / min.: Level 0, max: Level 31
    Changes depending on blower level (Rear)
    -
    Shift Set Temperature
    Shift set temperature
    Changes depending on shift set temperature *1
    -
    Air Inlet Mode
    Air inlet mode
    Changes depending on air inlet mode *1
    -
    Compressor Mode
    Compressor mode
    Changes depending on compressor mode *1
    -
    Compressor/DEF Mode
    Compressor/DEF operation mode
    Changes depending on compressor/DEF operation mode *1
    -
    Foot/DEF Auto Mode
    Foot/DEF auto mode
    Changes depending on Foot/DEF auto mode *1
    -
    Foot/DEF Auto Blow Up
    Foot/DEF automatic blow up function
    Changes depending on Foot/DEF automatic blow up function *1
    -
    Number of Trouble Codes
    Number of Trouble Codes / min.: 0, max.: 255
    -
    -

    HINT:
    *1: It differs depending on the user setting.


ACTIVE TEST

HINT:
Using Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Connect Techstream to the DLC3.

  2. Turn the ignition switch to the ON position.

  3. From the display on the tester, read the "Active Test".

    Air Conditioner / Active Test: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    min.: Level 0, max.: Level 31
    -
    Air Mix Damper (D Side)
    Air mix damper (D side)
    min.: -14%, max: 113.5%
    -
    Air Mix Damper (P Side)
    Air mix damper (P side)
    min.: -14%, max: 113.5%
    -
    Air Outlet Damper Position (D Side)
    Air outlet damper position (D side)
    min.: -14%, max: 113.5%
    -
    Air Inlet Damper Position (Linear)
    Air inlet damper position (linear)
    min.: -14%, max: 113.5%
    -
    Blower Motor (Rear)
    Blower motor (Rear)
    OFF, LO, HI
    -
    Air Mix Damper (Rear)
    Air mix damper (Rear)
    min.: -14%, max: 113.5%
    -
    Air Outlet Damper Position (Rear)
    Air outlet damper position (Rear)
    min.: -14%, max: 113.5%
    -
    Magnetic Clutch Relay
    Magnetic clutch relay
    OFF, ON
    -