Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › REAR BLOWER RESISTOR

REAR BLOWER RESISTOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT REAR BLOWER MOTOR CONTROLLER


    E032877
  1. Measure resistance according to the value(s) in the table below..

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 4
    Always
    2.0 to 2.4 kΩ

    If the resistance is not as specified, replace the rear blower motor controller.



    E147379E02
  1. Inspect the rear blower motor controller.

    1. Connect the positive (+) lead to terminal 3 through a 12 V to 3.4 W test bulb and negative (-) lead to terminal 1.

    2. Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 2, and the negative (-) lead to terminal 1. Then check that the test bulb comes on.

      OK:
      The test bulb comes on.

      If operation is not as specified, replace the rear blower motor controller.