Home › BODY ELECTRICAL › LIGHTING › LIGHTING SYSTEM

DTC    B1244    Light Sensor Circuit Malfunction

for Preparation Click here


DESCRIPTION

This DTC is output when failure in the light sensor circuit is detected.

DTC No.
DTC Detection Condition
Trouble Area
B1244
  1. Malfunction of automatic light control sensor
  2. Open or short of automatic light control sensor circuit
  1. Automatic light control sensor
  2. Harness or connector
  3. Multiplex network body ECU

WIRING DIAGRAM


E115587E03


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Body / Data List.

  1. Read the display on the Techstream.

    Body 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Illumination Rate
    Illumination rate information / 0 ms to 99.99 ms
    0.8 ms to 22.0 ms (Value is output according to ambient light levels)
    -

    OK:
    Normal condition listed above is displayed.



OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
NG


2.CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR)
  1. Check for open or short circuit in the harness and the connector between the terminal 6 of the automatic light control sensor and the terminal B6-6 of the multiplex network body ECU (Click here).

  1. Check for open or short circuit in the harness and the connector between the terminal 3 of the automatic light control sensor and the terminal B6-4 of the multiplex network body ECU (Click here).

  1. Check for open or short circuit in the harness and the connector between the terminal 5 of the automatic light control sensor and the terminal B6-5 of the multiplex network body ECU (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
  1. Measure voltage between the terminal 3 and the terminal 5 of the automatic light control sensor.

    Standard:

    Tester connection
    Condition
    Specified voltage
    3 - 5
    Ignition switch OFF → ON
    Signal wave form



OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
NG


4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


  1. Measure voltage between the terminal B6-6 and the terminal B6-4 of the multiplex network body ECU in the instrument panel junction block assembly.


    E067349E02


    Voltage:

    Tester connection
    Condition
    Specified voltage
    B6-4 - B6-6
    Ignition switch OFF → ON
    10 to 14 V



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK

REPLACE AUTOMATIC LIGHT CONTROL SENSOR