Home › BODY ELECTRICAL › LIGHTING › LIGHTING SYSTEM

LIGHTING SYSTEM > Ignition Switch Circuit

for Preparation Click here


DESCRIPTION

The Multiplex network body ECU receives the ACC and IG signals from the ignition switch.

WIRING DIAGRAM


E116042E07


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Body / Data List.

  1. Read the display on the Techstream.

    Body 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    ACC SW
    ACC SW signal / ON or OFF
    ON: Ignition key is in ACC, ON or START position
    OFF: Ignition key is in OFF position
    -
    IG SW
    IG SW signal / ON or OFF
    ON: Ignition key is in ON or START position
    OFF: Ignition key is in OFF or ACC position
    -

    OK:
    Normal conditions listed above are displayed.



OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG


2.INSPECT FUSE
  1. Inspect the ECU ACC fuse, ECU-IG fuse and AM1 fuse in instrument panel junction block assembly.



NG
REPLACE FUSE
OK


3.INSPECT RELAY


    E064835E08
  1. Inspect ACC relay continuity.

    Resistance:
    Condition
    Tester Connection
    Specified Condition
    Always
    3 - 5
    10 kΩ or higher
    Apply B+ between the terminal 1 and 2
    3 - 5
    Below 1 Ω



    E064835E09
  1. Inspect IG1 relay continuity.

    Resistance:
    Condition
    Tester Connection
    Specified Condition
    Always
    3 - 5
    10 kΩ or higher
    Apply B+ between the terminal 1 and 2
    3 - 5
    Below 1 Ω



NG
REPLACE RELAY
OK


4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


  1. Measure the voltage between the terminals as shown in the chart below.

    Voltage:

    Tester Connection
    Condition
    Specified Condition
    1H-9 - Body ground
    Ignition switch is OFF → ACC, ON
    Below 1 V → 10 to 14 V
    1H-29 - Body ground
    Ignition switch is OFF → ON
    Below 1 V → 10 to 14 V


    E067349E03



OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG


5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


  1. Measure voltage between the terminal 1A-1 of the instrument panel junction block assembly and body ground.

    Voltage:

    Tester connection
    Specified voltage
    1A-1 - Body ground
    10 to 14 V


    E067348E02



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


  1. Measure voltage between the terminal 1H-10 of the instrument panel junction block assembly and body ground.

    Voltage:

    Tester Connection
    Condition
    Specified Condition
    1H-10 - Body ground
    Always
    10 to 14 V


    E067349E04



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR