LIGHTING SYSTEM > DRL Relay Circuit |

| 1.PERFORM ACTIVE TEST USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Body / Active Test.
Check the operation.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Relay of DRL | Relay of DRL (Ignition SW is ON, engine is stopped and light control SW is in OFF position). | ON/OFF | - |
|
| ||||
| NG | |
| 2.INSPECT DRL NO.2 RELAY |
![]() |
Inspect DRL No.2 Relay continuity.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Always | 10 kΩ or higher |
| 3 - 5 | Apply B+ between the terminal 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (POWER SOURCE) |
![]() |
Disconnect the connector from the instrument panel junction block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1C-23 - Body ground | Always | 10 to 14 V |
|
| ||||
| OK | |
| 4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Reconnect the connector to the instrument panel junction block assembly.

Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1C-23 - Body ground | Ignition switch: OFF | 10 to 14 V |
| 1C-23 - Body ground | Ignition switch: ON | Below 1 V |
|
| ||||
| OK | |
| 5.INSPECT RELAY (DRL NO.3, DRL NO.4) |
![]() |
Inspect DRL NO.4 Relay continuity.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Always | 10 kΩ or higher |
| 3 - 5 | Apply B+ between the terminal 1 and 2 | Below 1 Ω |
![]() |
Inspect DRL NO.3 Relay continuity.
| Tester Connection | Condition | Specified Condition |
| 3 - 4 | Always | Below 1 Ω |
| 3 - 4 | Apply B+ between the terminal 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Always | 10 kΩ or higher |
| 3 - 5 | Apply B+ between the terminal 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 6.INSPECT DAYTIME RUNNING LIGHT RESISTER |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | Always | 0.94 to 1.04 Ω |
|
| ||||
| OK | ||
| ||