Home › BODY ELECTRICAL › LIGHTING › LIGHTING SYSTEM

LIGHTING SYSTEM > Automatic Light Control Sensor Circuit

for Preparation Click here


DESCRIPTION

The Multiplex network body ECU receives the signal from the automatic light control sensor.

HINT:
DTC code is output when malfunction of automatic light control sensor or open or short of automatic light control sensor circuit occurs.


WIRING DIAGRAM


E115587E05


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Body / Data List.

  1. Read the display on the Techstream.

    Body 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Illumination Rate
    Illumination rate information / 0 ms to 99.99 ms
    0.8 ms to 22.0 ms (Value is output according to ambient light levels)
    -

    OK:
    Normal condition listed above is displayed.



OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG


2.CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR)
  1. Check for open or short circuit in the harness and the connector between the terminal 6 of the automatic light control sensor and the terminal B6-6 of the multiplex network body ECU (Click here).

  1. Check for open or short circuit in the harness and the connector between the terminal 3 of the automatic light control sensor and the terminal B6-4 of the multiplex network body ECU (Click here).

  1. Check for open or short circuit in the harness and the connector between the terminal 5 of the automatic light control sensor and the terminal B6-5 of the multiplex network body ECU (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


  1. Measure voltage between the terminal B6-4 and the terminal B6-6 of the multiplex network body ECU in the instrument panel junction block assembly.


    E067349E13


    Voltage:

    Tester Connection
    Condition
    Specified Condition
    B6-4 - B6-6
    Ignition switch OFF → ON
    10 to 14 V



NG
REPLACE AUTOMATIC LIGHT CONTROL SENSOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE