LIGHTING SYSTEM > Automatic Light Control Sensor Circuit |

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Body / Data List.
Read the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Illumination Rate | Illumination rate information / 0 ms to 99.99 ms | 0.8 ms to 22.0 ms (Value is output according to ambient light levels) | - |
|
| ||||
| NG | |
| 2.CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR) |
Check for open or short circuit in the harness and the connector between the terminal 6 of the automatic light control sensor and the terminal B6-6 of the multiplex network body ECU (Click here).
Check for open or short circuit in the harness and the connector between the terminal 3 of the automatic light control sensor and the terminal B6-4 of the multiplex network body ECU (Click here).
Check for open or short circuit in the harness and the connector between the terminal 5 of the automatic light control sensor and the terminal B6-5 of the multiplex network body ECU (Click here).
|
| ||||
| OK | |
| 3.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Measure voltage between the terminal B6-4 and the terminal B6-6 of the multiplex network body ECU in the instrument panel junction block assembly.

| Tester Connection | Condition | Specified Condition |
| B6-4 - B6-6 | Ignition switch OFF → ON | 10 to 14 V |
|
| ||||
| OK | ||
| ||