HAZARD WARNING SWITCH > INSPECTION |
| 1. HAZARD WARNING SIGNAL SWITCH ASSEMBLY |
![]() |
Check that there is resistance between the terminals at each switch position as shown in the chart.
| Switch operation | Tester connection | Specified condition |
| OFF | 3 - 4 | 10 kΩ or higher |
| ON | 3 - 4 | Below 1 Ω |
| Illumination circuit | 5 - 6 | Below 1 Ω |
Inspect illumination operation.
Connect the positive (+) lead from the battery to the terminal 6 and negative (-) lead to the terminal 5, then check that the illumination comes on.