Home › BODY ELECTRICAL › LIGHTING › HAZARD WARNING SWITCH

HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    I035767
  1. Check that there is resistance between the terminals at each switch position as shown in the chart.

    Resistance:
    Switch operation
    Tester connection
    Specified condition
    OFF
    3 - 4
    10 kΩ or higher
    ON
    3 - 4
    Below 1 Ω
    Illumination circuit
    5 - 6
    Below 1 Ω

  1. Inspect illumination operation.

    1. Connect the positive (+) lead from the battery to the terminal 6 and negative (-) lead to the terminal 5, then check that the illumination comes on.