Home › BODY ELECTRICAL › NAVIGATION › NAVIGATION SYSTEM

NAVIGATION SYSTEM > Pressing Power Switch does not Turn on System

for Preparation Click here


INSPECTION PROCEDURE

1.CHECK CABIN
  1. Check that conditions in the cabin are not likely to cause condensation.

    HINT:
    This problem occurs when the cabin is humid and the temperature rapidly changes. This condition may produce condensation, resulting in a short circuit.

    OK:
    Condensation is not likely to occur.



NG
DRY CABIN AND RECHECK CONDITIONS
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE