Home › ENGINE › 2GR-FE EMISSION CONTROL › HEATED OXYGEN SENSOR (for 2WD)

HEATED OXYGEN SENSOR (for 2WD) > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    A161881E02
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (HT) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT) - 4 (E1)
    10 kΩ or higher

    If the resistance is not as specified, replace the sensor.



2. INSPECT HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


    A161881E04
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 (HT) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    3 (HT) - 4 (E1)
    10 kΩ or higher

    If the resistance is not as specified, replace the sensor.