Home
›
BODY ELECTRICAL
›
LIGHTING
›
LIGHT CONTROL RELAY
LIGHT CONTROL RELAY > ON-VEHICLE INSPECTION
for Preparation
Click here
1. LIGHT CONTROL RELAY
Inspect relay resistance.
Resistance:
Condition
Tester Connection
Specified Condition
Always
3 - 5
10 kΩ to higher
Apply B+ between the terminal 1 and 2
3 - 5
Below 1 Ω