VOLTAGE INVERTER > INSPECTION |
| 1. INSPECT INVERTER MAIN SWITCH |
![]() |
Measure the resistance at the each switch position shown in the table below.
| Switch operation | Tester connection | Specified condition |
| OFF | 3 - 2 | 10 kΩ or higher |
| ON | 3 - 2 | Below 1 Ω |
Inspect the bulb state when connecting the battery to each terminal.
| Inspection item | Battery connection | Specified condition |
| Indicator | Battery positive terminal - 3 Battery negative terminal - 5 | Comes on |
| Illumination | Battery positive terminal - 4 Battery negative terminal - 1 | Comes on |
![]() |
Inspect continuity of the bulb by connecting the tester as shown in the illustration.
If continuity exists, replace the main switch assembly.
If no continuity exists, replace the bulb.
| 2. INSPECT INVERTER RELAY |
![]() |
Measure the resistance at the each switch position shown in the table below.
| Condition | Tester connection | Specified condition |
| Always | 1 - 2 | Below 1 Ω |
| Always | 3 - 5 | 10 kΩ or higher |
| Apply B+ between terminal 1 and 2 | 3 - 5 | Below 1 Ω |