AIR CONDITIONING PRESSURE SENSOR > ON-VEHICLE INSPECTION |
| 1. INSPECT A/C PRESSURE SENSOR |
Install the manifold gauge set.
Disconnect the connector from the A/C pressure sensor.
![]() |
Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3 and the negative (-) lead to terminal 1.
Connect the voltmeter's positive (+) lead to terminal 2 and the negative (-) lead to terminal 1.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 - 1 | Refrigerant pressure: 0.39 to 3.187 MPa (57 to 463 psi) | 1.0 to 4.8 V |