DTC P2714 Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P2714 | ECM detects a malfunction on SLT (ON side) according to the revolution difference of the turbine, intermediate and the output shaft, and also by the oil pressure. (2-trip detection logic) |
|
| Related DTCs | P2714: Shift solenoid valve SLT/ON malfunction |
| Required sensors/Components | Shift solenoid valve SLT, Speed sensor (NT), Speed sensor (NC), Crankshaft position sensor (NE) |
| Frequency of operation | Continuous |
| Duration | 0.5 sec. |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| Transmission range | "D" |
| TFT (Transmission fluid temperature) | -20°C (-4°F) or more |
| TFT sensor circuit | Not circuit malfunction |
| Turbine speed sensor circuit | Not circuit malfunction |
| Intermediate shaft speed sensor circuit | Not circuit malfunction |
| Output speed sensor circuit | Not circuit malfunction |
| Shift solenoid valve SL1 circuit | Not circuit malfunction |
| Shift solenoid valve SL2 circuit | Not circuit malfunction |
| Shift solenoid valve SL3 circuit | Not circuit malfunction |
| Shift solenoid valve S4 circuit | Not circuit malfunction |
| Shift solenoid valve SR circuit | Not circuit malfunction |
| Shift solenoid valve DSL circuit | Not circuit malfunction |
| Shift solenoid valve SLT circuit | Not circuit malfunction |
| Electronic throttle system | Not circuit malfunction |
| ECM selected gear | 1st |
| Temporary MAIN gear | 1st or 2nd or 3rd or 4th |
| NT - NC x Temporary MAIN gear ratio NT: Input (turbine) speed NC: Intermediate shaft speed | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| Temporary U/D gear | Low |
| NC - NO x Temporary U/D gear ratio NO: Output speed | 300 rpm or more at Output speed 1,000 rpm |
| TT TT: Turbine Torque | 900 Nm or more |
| NT | 250 rpm or more |
| NC | 250 rpm or more |
| NO | 250 rpm or more |
| ECM selected gear | 2nd |
| Temporary MAIN gear | 1st or 2nd or 3rd or 4th |
| NT - NC x Temporary MAIN gear ratio NT: Input (turbine) speed NC: Intermediate shaft speed | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| Temporary U/D gear | Low |
| NC - NO x Temporary U/D gear ratio NO: Output speed | 300 rpm or more at Output speed 1,000 rpm |
| TT TT: Turbine Torque | 900 Nm or more |
| NT | 250 rpm or more |
| NC | 250 rpm or more |
| NO | 250 rpm or more |
| ECM selected gear | 3rd |
| Temporary MAIN gear | 1st or 2nd or 3rd or 4th |
| NT - NC x Temporary MAIN gear ratio NT: Input (turbine) speed NC: Intermediate shaft speed | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| Temporary U/D gear | Low |
| NC - NO x Temporary U/D gear ratio NO: Output speed | 300 rpm or more at Output speed 1,000 rpm |
| TT TT: Turbine Torque | 900 Nm or more |
| NT | 250 rpm or more |
| NC | 250 rpm or more |
| NO | 250 rpm or more |
| ECM selected gear | 4th |
| Temporary MAIN gear | 1st or 2nd or 3rd or 4th |
| NT - NC x Temporary MAIN gear ratio NT: Input (turbine) speed NC: Intermediate shaft speed | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| Temporary U/D gear | Low |
| NC - NO x Temporary U/D gear ratio NO: Output speed | 300 rpm or more at Output speed 1,000 rpm |
| TT TT: Turbine Torque | 245 Nm or more |
| NT | 250 rpm or more |
| NC | 250 rpm or more |
| NO | 250 rpm or more |
| ECM selected gear | 5th |
| Temporary MAIN gear | 1st or 2nd or 3rd or 4th |
| NT - NC x Temporary MAIN gear ratio NT: Input (turbine) speed NC: Intermediate shaft speed | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| Temporary U/D gear | Low |
| NC - NO x Temporary U/D gear ratio NO: Output speed | 300 rpm or more at Output speed 1,000 rpm |
| TT TT: Turbine Torque | 245 Nm or more |
| NT | 250 rpm or more |
| NC | 250 rpm or more |
| NO | 250 rpm or more |
| NT - NC x 1st gear ratio | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| NC - NO x Low gear ratio | 300 rpm or more at Output speed 1,000 rpm |
| Duration | 1 sec. or more |
| Shift Solenoid valve SL1 Performance | Not performance malfunction |
| NT - NC x 2nd gear ratio | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| NC - NO x Low gear ratio | 300 rpm or more at Output speed 1,000 rpm |
| Duration | 1 sec. or more |
| Shift Solenoid valve SL1 Performance | Not performance malfunction |
| NT - NC x 3rd gear ratio | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| NC - NO x Low gear ratio | 300 rpm or more at Output speed 1,000 rpm |
| Duration | 1 sec. or more |
| Shift Solenoid valve SL1 Performance | Not performance malfunction |
| NT - NC x 4th gear ratio | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| NC - NO x Low gear ratio | 300 rpm or more at Output speed 1,000 rpm |
| Duration | 1 sec. or more |
| Shift Solenoid valve SL1 Performance | Not performance malfunction |
| NT - NC x 4th gear ratio | 100 rpm or more at Intermediate shaft speed 1,000 rpm |
| NC - NO x High gear ratio | 300 rpm or more at Output speed 1,000 rpm |
| Duration | 1 sec. or more |
| Shift Solenoid valve SL1 Performance | Not performance malfunction |
| 1.CHECK OTHER DTCS OUT PUT (IN ADDITION TO DTC P2714) |
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position and turn the Techstream main switch ON.
When you use Techstream:
Select the item "Powertrain / Engine and ECT / Trouble Codes"
Read the DTCs using Techstream.
| Result | Proceed to |
| P2714 | A |
| P2714 and other DTCs | B |
|
| ||||
| A | |
| 2.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 1-2 | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | |
| 3.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
|
| ||||
| OK | |
| 4.INSPECT TORQUE CONVERTER CLUTCH ASSEMBLY |
|
| ||||
| OK | ||
| ||