Home › ENGINE › 2GR-FE INTAKE › VACUUM SWITCHING VALVE

VACUUM SWITCHING VALVE > INSPECTION

for Preparation Click here



1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY


    A075331E02
  1. Inspect VSV operation.

    1. Using an ohmmeter, measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Terminals
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      37 to 44 Ω

      If the result is not as specified, replace the VSV.



  1. Inspect the VSV for ground.



      A075332E03
    1. Using an ohmmeter, measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Terminals
      Condition
      Specified Condition
      1 - Body ground
      20°C (68°F)
      10 kΩ or higher
      2 - Body ground
      20°C (68°F)
      10 kΩ or higher

      If the result is not as specified, replace the VSV.



    2. A126855E01
    3. Inspect VSV operation.

      1. Check that air flows from port E to the filter.
      2. Apply battery voltage across the terminals.
      3. Check that air flows from port E to port F.
      If operation is not as specified, replace the VSV.