INTAKE AIR CONTROL VALVE > INSTALLATION |
| 1. INSTALL NO. 3 INTAKE AIR CONTROL VALVE ASSEMBLY |
![]() |
Engage the 2 claws and install the No. 3 intake air control valve assembly.
| 2. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
![]() |
Install the air cleaner filter element, and air cleaner cap sub-assembly with the 2 bolts.
![]() |
Connect the 3 vacuum hoses.
![]() |
Tighten the bolt, connect the 2 connectors, and install the 2 vacuum hoses.
| 3. INSTALL NO. 2 AIR CLEANER INLET |
![]() |
Install the No. 2 air cleaner inlet with the 2 clamps and 2 bolts.