Home › ENGINE › 2GR-FE INTAKE › INTAKE AIR CONTROL VALVE

INTAKE AIR CONTROL VALVE > INSTALLATION

for Preparation Click here



1. INSTALL NO. 3 INTAKE AIR CONTROL VALVE ASSEMBLY


    A162725
  1. Engage the 2 claws and install the No. 3 intake air control valve assembly.



2. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    A161845
  1. Install the air cleaner filter element, and air cleaner cap sub-assembly with the 2 bolts.

    Torque:
    5.0 N*m{ 50 kgf*cm , 44 in.*lbf }



    A162723E01
  1. Connect the 3 vacuum hoses.



    A162726
  1. Tighten the bolt, connect the 2 connectors, and install the 2 vacuum hoses.



3. INSTALL NO. 2 AIR CLEANER INLET


    A133004
  1. Install the No. 2 air cleaner inlet with the 2 clamps and 2 bolts.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }