Home › COMMUNICATION SYSTEM › CAN COMMUNICATION › CAN COMMUNICATION SYSTEM

CAN COMMUNICATION SYSTEM > Distance Control ECU Communication Stop Mode

for Preparation Click here


DESCRIPTION


Detection Item
Symptom
Trouble Area
Distance Control ECU Communication Stop Mode
  1. "Distance control" is not displayed on the "Communication Bus Check" screen of the Techstream
  2. Applies to "Distance Control ECU Communication Stop Mode" in the "DTC COMBINATION TABLE"
  1. Power source circuit of distance control ECU
  2. Distance control ECU branch wire or connector
  3. Distance control ECU

WIRING DIAGRAM


C161528E01


INSPECTION PROCEDURE

NOTICE:
  1. Turn the ignition switch off before measuring the resistances of CAN bus main wires and CAN bus branch wires.
  2. After the ignition switch is turned off, check that the key reminder warning system and light reminder warning system are not in operation.
  3. Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the ignition switch, any other switches, or the doors. If any doors need to be opened in order to check connectors, open the doors and leave them open.

HINT:
Operating the ignition switch, any switches, or any doors triggers related ECU and sensor communication with the CAN. This communication will cause the resistance value to change.

1.CHECK OPEN IN CAN BUS WIRE (DISTANCE CONTROL ECU)
  1. Turn the ignition switch off.

  1. Disconnect the distance control ECU connector.



    C161530E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D2-8 (CANH) - D2-9 (CANL)
    Ignition Switch off
    54 to 69 Ω



NG
REPAIR OR REPLACE DISTANCE CONTROL ECU BRANCH WIRE OR CONNECTOR
OK


2.CHECK WIRE HARNESS (B, GND)


    C161530E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D2-12 (GND) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D2-1 (B) - Body ground
    Ignition Switch on
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE DISTANCE CONTROL ECU ASSEMBLY (Click here)