Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Blower Motor Circuit

for Preparation Click here


DESCRIPTION

E145209E01
The blower motor is operated by signals from the A/C amplifier. Blower motor speed signals are transmitted by changes in the Duty Ratio.
Duty Ratio
  1. The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A+B) x 100 (%).
E145208E01

WIRING DIAGRAM


C119463E03


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Data List, and read the display on Techstream.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Blower Motor Speed Level
    Blower motor speed level / min.: Level 0, max.: Level 31
    Changes depending on blower level
    -

    OK:
    The display is as specified in the normal condition column.



NG
Go to step 2
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE 

2.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn Techstream on.

  1. Select the item below in the Active Test and then check that the blower motor operates.

    Active Test / Air Conditioner: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor speed level
    min.: Level 0, max.: Level 31
    -

    OK:
    The blower motor operates and the blower level changes.



NG
Go to step 3
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE 

3.PERFORM ACTUATOR CHECK
  1. Enter the actuator check mode (Click here).

  1. Press the DEF switch to change to the step operation.

  1. Check the air flow level by hand.

    Display Code
    Blower Level
    0
    0
    1
    1
    2
    17
    3
    17
    4
    17
    5
    17
    6
    17
    7
    17
    8
    17
    9
    31

    OK:
    The blower level changes in accordance with each display code.



NG
Go to step 4
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE 

4.INSPECT BLOWER MOTOR


    E147349E01
  1. Remove the blower motor.

  1. Disconnect the connector from the blower motor.

  1. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the motor operates.

    OK:
    Blower motor operates smoothly.



NG
REPLACE BLOWER MOTOR
OK


5.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BLOWER MOTOR CONTROLLER)
  1. Disconnect the connector from the blower motor.



    E147584E01
  1. Disconnect the connector from the blower motor controller.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B2-2 - B3-2 (VM)
    Always
    Below 1 Ω
    B2-2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)


    E145472E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B2-1 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROLLER - BODY GROUND)


    E147376E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B3-6 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROLLER - BATTERY)


    E147376E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    B3-1 (+B) - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - BLOWER MOTOR CONTROLLER)


    E147585E01
  1. Disconnect the connector from the A/C amplifier.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A9-6 (BLW) - B3-3 (SI)
    Always
    Below 1 Ω
    A9-6 (BLW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.INSPECT A/C AMPLIFIER


    E147476E01
  1. Reconnect the connector to the A/C amplifier.

  1. Reconnect the connector to the blower motor controller.

  1. Reconnect the connector to the blower motor.



    E103396E01
  1. Measure the waveform between terminal A9-6 (BLW) of the A/C amplifier and body ground.

    OK:
    Waveform is as shown in the illustration.

    HINT:
    Waveform varies with the blower level.

    Item
    Contents
    Tool Setting
    1 V/DIV., 500 μs/DIV.
    Vehicle Condition
    Ignition switch: ON
    Blower switch: LO



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BLOWER MOTOR CONTROLLER