Home › Engine / Hybrid System › B48 (COOLING) › COOLING SYSTEM
NM3650E _51 Engine / Hybrid System _081996 B48 COOLING _0395825 COOLING SYSTEM GE GENERAL F

B48 COOLING  COOLING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

Optimum utilization of the installation space thanks to powerful radiators, with advanced pipe and vane technology, indirect charge air cooling and a capacitor cooled using coolant.


b.

The cooling system has been split into 2 separate circuits: a high temperature cooling circuit to cool the engine unit, and a low temperature cooling circuit to cool the intercooler, etc. For the low temperature cooling circuit, refer to the B48 INTAKE/EXHAUST section.


c.

The coolant temperatures are controlled by the coolant flow control by the heat management module (water valve) and electric fan control as necessary.


d.

The fan with motor assembly is installed behind the radiator assembly.


e.

The ECM controls the fan with motor assembly drive according to operating conditions.


f.

Consistent reduction in cost and weight thanks to use of more plastic tubes.


g.

All the coolant circuits can be opened separately for service purposes; all cooling related components can be removed individually. This leads to low service costs.


h.

Acoustically decoupled cooling packages and engine oil cooler lines/oil cooler assembly. And thus acoustic goals have been met.


i.

A coolant shutoff valve has been provided to shut off the pathways between the high temperature cooling circuit and the coolant tank during cold starts. This allows the engine to be warmed up quickly, achieving a reduction in CO2 emissions.



MAIN FEATURES


a.

Indirect charge air cooling has been adopted for the supercharged air for optimal functional and cost design for the relevant use spectrum.


b.

Platform software that is divided into modules permits the control of all cooling system components as required.


c.

Multiple signals from the ECM and other control units are processed and heat management is configured for the current driving and ambient conditions. The objective hereby is always to ensure the greatest possible energy-efficient, consumption-optimized and thermally safe, and inconspicuous for the customer, operation of the engine, automatic transmission and all other components of the drive train.


d.

The thermal management implements the operation strategy for all involved actuators, such as electric water pumps, volume flow controls, air flap controllers and electric fans. The thermal management and also affects the engine management in the ECM.