FEATURES
A variable cooling system has been adopted via a heat management module (water valve) which uses a rotary valve and an integrated electric split cooling valve, providing appropriate cooling for various driving conditions.
Cold start
The rotary valve inside the heat management module (water valve) closes, and coolant is circulated within the water inlet housing with water pump sub-assembly.
| *1 | Water Inlet Housing with Water Pump Sub-assembly | *2 | Heat Management Module (Water Valve) |
| *a | Coolant | *b | The illustrations shown are examples only. |
Warm up
The cylinder head, turbocharger, etc. are cooled according to the opening of the rotary valve of the heat management module (water valve). The coolant pathway to the cylinder block is closed by the electric split cooling valve.
| *1 | Water Pump Assembly (for Turbocharger) | *2 | Turbocharger |
| *3 | Cylinder Head Sub-assembly | *4 | Engine Coolant Temperature Sensor (for Engine) |
| *5 | Oil Cooler Assembly | *6 | Heater Radiator Unit Sub-assembly |
| *7 | Heat Management Module (Water Valve)
·
Electric Split Cooling Valve |
*8 | Coolant Shutoff Valve |
| *9 | Water Inlet Housing with Water Pump Sub-assembly | - | - |
| *a | High Temperature Coolant | *b | Low Temperature Coolant |
| *c | The illustrations shown are examples only. | - | - |
Engine operating temperature
Coolant flow volume through the various coolant pathways is varied according to engine load.
| *1 | Radiator Assembly | *2 | Engine Coolant Temperature Sensor (for Radiator) |
| *3 | Water Pump Assembly (for Turbocharger) | *4 | Turbocharger |
| *5 | Cylinder Head Sub-assembly | *6 | Engine Coolant Temperature Sensor (for Engine) |
| *7 | Oil Cooler Assembly | *8 | Heater Radiator Unit Sub-assembly |
| *9 | Heat Management Module (Water Valve)
·
Electric Split Cooling Valve |
*10 | Coolant Shutoff Valve |
| *11 | Water Inlet Housing with Water Pump Sub-assembly | *12 | Fan with Motor Assembly |
| *a | High Temperature Coolant | *b | Low Temperature Coolant |
| *c | The illustrations shown are examples only. | - | - |
Maximum cooling is requested
The connection with the radiator assembly is fully open, and the electric split cooling valve opens to deliver maximum cooling efficiency.
| *1 | Radiator Assembly | *2 | Engine Coolant Temperature Sensor (for Radiator) |
| *3 | Water Pump Assembly (for Turbocharger) | *4 | Turbocharger |
| *5 | Cylinder Head Sub-assembly | *6 | Engine Coolant Temperature Sensor (for Engine) |
| *7 | Cylinder Block | *8 | Oil Cooler Assembly |
| *9 | Heater Radiator Unit Sub-assembly | *10 | Heat Management Module (Water Valve)
·
Electric Split Cooling Valve |
| *11 | Oil Temperature Sensor | *12 | Coolant Shutoff Valve |
| *13 | Water Inlet Housing with Water Pump Sub-assembly | *14 | Fan with Motor Assembly |
| *a | High Temperature Coolant | *b | Low Temperature Coolant |
| *c | The illustrations shown are examples only. | - | - |