NETWORKING  MULTIPLEX COMMUNICATION SYSTEM [MOST]  GENERAL  GENERAL  


OUTLINE


a.

The MOST (Media Oriented Systems Transport) bus uses a ring bus for data traffic between the various control units. Signal transmission is by means of optical fiber. Data transmission on the ring bus takes place in one direction only. On the MOST ring, messages can only be transmitted provided the bus ring is complete and fully functional. If the ring is broken, diagnosis communication is only possible with the radio receiver assembly.


b.

Due to the ring structure of the MOST, a component fault often affects the complete system. A component fault thus generates fault memory entries in a number of control units.


c.

The following test procedures are available:

·

MOST system analysis

·

Deactivation, MOST excess temperature

·

MOST ring saving function by the radio receiver assembly



d.

The MOST system analysis analyzes all communication faults with MOST control units.


e.

The "MOST system analysis" test procedure also assesses the stability (MOST ring broken or unbroken) and the order of the control units in the MOST ring.


f.

The ring break diagnosis is integrated in the MOST system analysis. For that purpose the order of the MOST control units in the ring is read out and the location of the ring break indicated.


g.

If a control unit becomes too hot, this control unit switches off for up to 10 minutes. Furthermore, the entire MOST bus can switch off for 10 minutes. After the control unit has cooled down, it becomes functional once again.


h.

The following 2 redundant fault entries for shutdown due to excess temperature are present:

i.

MOST control unit: Deactivation, excess temperature

·

This fault entry is entered in the radio receiver assembly if the radio receiver assembly has detected a shutdown due to excess temperature in another control unit.



ii.

Radio receiver assembly: High temperature cut-out

·

The fault entry is entered in every single MOST device that shuts down in response as a consequence of excess temperature.




i.

The specified configuration of the MOST ring (the control units fitted and the order they are arranged in the MOST ring) is stored in the radio receiver assembly. If a control unit is retrofitted or the radio receiver assembly is replaced, the specified configuration must be saved again. The desired configuration is carried out with the programming (ISTA/P). Then, if a break in the ring occurs, the specified configuration can be used to determine between which control units the break is located.

HINT:

The MOST control units are programmed via Ethernet.



j.

Integrated in the MOST control units is an Intelligent Network Interface Controller (INIC). The INIC is the transmitter and receiver module in the MOST control unit. The INIC itself is a fully functional, autonomous network node. The network node can operate the fundamental network functions without interaction with its application. This means that the MOST ring remains functional even if a control unit has failed or is running a reset.