Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
NM3650E _58 Vehicle Interior _082880 HEATING / AIR CONDITIONING _0399821 AIR CONDITIONING SYSTEM CO CONTROL F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  CONTROL  AIR CONDITIONING CONTROL  


SYSTEM CONTROL


a.

Temperature Control

i.

The setpoint values are set using 2 temperature selector wheels (separate settings for left and right sides) on the air conditioning control assembly. The air conditioning amplifier assembly uses the selected potentiometer setting to regulate the flap motors (No. 1 air conditioning radiator damper servo sub-assembly).


ii.

The actual value is calculated from the temperatures measured by the ventilation temperature sensor (No. 3 cooler thermistor) and the footwell temperature sensor (No. 1 cooler thermistor). The reference variable is calculated from the comparison between the actual value for the interior temperature and the corrected setpoint value (calculated from temperature selector wheel setting and ambient temperature). When the interior temperature is cold compared to the specified setpoint value, the interior temperature is raised so that a comfortable level is achieved even at negative temperatures, despite the temperature setting being unchanged. The ambient temperature is transmitted to the air conditioning amplifier assembly via the CAN bus.


iii.

The flap motors (No. 1 air conditioning radiator damper servo sub-assembly) communicate across the LIN bus with the air conditioning amplifier assembly. The air conditioning amplifier assembly supplies the flap motors (No. 1 air conditioning radiator damper servo sub-assembly) with voltage and ground. In the idle state, the air conditioning amplifier assembly switches the supply voltage off.



b.

Evaporator Control

i.

The air conditioning amplifier assembly regulates the No. 1 cooler evaporator sub-assembly temperature with the aid of the evaporator temperature sensor (No. 2 cooler thermistor) and the cooler expansion valve.



c.

Air Distribution

i.

Occupants can allow the air distribution to be managed by the automatic program. Alternatively, individuals can choose to select blower outlets manually.



d.

Air Flow Control

i.

The air flow control is dependent on the following settings and control actions:

·

Automatic blower and flap control

-

The automatic blower and flap functions are activated when the AUTO switch is pressed.


·

Ram air pressure compensation

-

The air mass at the air intake grilles increases with increasing driving speed. This effect is compensated for by the opening angle of the fresh air flap being reduced as speed increases (ram air pressure compensation). The opening angle is controlled according to a defined characteristic curve.


·

Blower control

-

The blower switch can be used to set the amount of air manually.

-

In the automatic program, the air flow volume is increased or decreased automatically. According to the selected settings at the air conditioning control assembly, the air conditioning amplifier assembly controls the blower motor with fan sub-assembly via the LIN bus.

-

If necessary, the power management system will assign priority levels to reduce the blower output (via the CAN bus).


·

Influence on engine starting

-

When the engine is being started, the blower is switched OFF to reduce the load on the vehicle battery.





e.

Sunlight Adaptation

i.

The solar sensor (rain sensor) enables the air conditioning system to take into account the effects of direct sunlight. The solar sensor (rain sensor) senses direct sunlight that affects the climate in the passenger compartment. The main body ECU (multiplex network body ECU) outputs the sensor signals as a message on the CAN bus to the air conditioning amplifier assembly.


ii.

If a solar sensor (rain sensor) is installed, the following functions change in response to the intensity of direct sunlight when automatic program is activated:

·

Blower output is increased or reduced

·

Nominal temperature value is increased or reduced



iii.

How the solar sensor (rain sensor) affects the integrated automatic air conditioning system control is determined separately for the driver and passenger sides.



f.

MAX Cooling

i.

When the MAX A/C switch is pressed, the air conditioning amplifier assembly prompts all functions, including the defrost function, to be deactivated. The air conditioning function is activated (if it was not already activated) and defined settings are selected (e.g. temperature control is deactivated, ventilation flaps are fully opened).



g.

Defrost Function

i.

The defroster flap is fully opened when the defrost function is switched on. The fresh air/recirculation flaps move to the fresh air position. All other flaps are closed. The blower is run at a specified output level.



h.

Automatic Function

i.

When the AUTO switch is lightly pressed, all integrated automatic air conditioning functions are set to automatic mode. Depending on the selected temperature, the air distribution and blower speed are set by the automatic program. If one or more automatically controlled functions are manually set, automatic control for the functions concerned will be cancelled. All other functions remain automatically controlled.


ii.

The information from the solar sensor (rain sensor) and condensation sensor (rain sensor) is also taken into account in the automatic program.



i.

Rear Defogger

i.

Request signals are sent from the air conditioning control assembly via the LIN bus to the air conditioning amplifier assembly. The air conditioning amplifier assembly acts as a data interface and transmits the request signal via the CAN bus. The main body ECU (multiplex network body ECU) controls the rear defogger.



j.

OFF

i.

The air conditioning system can be turned OFF by setting the blower speed to 0 using the air conditioning control assembly. The air conditioning amplifier assembly continues running in the background.



k.

Air Recirculation Function

i.

The air in the passenger compartment is continuously recirculated. To guarantee a sufficient fresh air supply, the air recirculation function is limited to a certain duration (e.g. 30 minutes air recirculation function -> 30 seconds partial fresh-air mode -> 30 minutes air recirculation function -> etc.).



l.

Automatic Air Recirculation Control

i.

If the smoke sensor detects an increased level of pollutants from engine in the outside air, the air conditioning amplifier assembly will automatically switch to air recirculation mode.


ii.

To ensure an adequate fresh air supply, the recirculated air mode has a time limit.


iii.

When the engine is started and the AUC function activated, fresh air is always selected for a few seconds (approx. 40 seconds) due to the warm-up phase of the smoke sensor.



m.

Condensation Prevention Program

i.

The condensation sensor (rain sensor) is able to detect condensation on the windshield before it becomes visible. The main body ECU (multiplex network body ECU) outputs the sensor signals as a message on the CAN bus to the air conditioning amplifier assembly. The air conditioning amplifier assembly evaluates the signal (air humidity) from the condensation sensor (rain sensor).


ii.

The following conditions must be satisfied for measures against condensation on the windows to be effected:

·

The engine is running.

·

The air conditioning system is in the automatic program.



iii.

If condensation on the windows is imminent, the following measures are initiated in sequence to prevent condensation from forming. If a measure is determined to be ineffective, the next measure is initiated. Once successful, the measures performed up to that point are cancelled step-by-step in the reverse order.

·

Measures taken when fogging of the windows appears imminent:

-

Open defroster flaps further

-

Switch to partial fresh-air mode from recirculation/AUC/automatic air recirculation mode

-

Switch from partial fresh-air mode in recirculation/AUC/automatic air recirculation mode to fresh air mode

-

Increase air mass with the blower

-

Reduce air mass from the footwell

-

Increase nominal temperature value