CONSTRUCTION
The air conditioner pressure sensor is installed in the high pressure line between the cooler condenser assembly and the No. 1 cooler evaporator sub-assembly. While cooling, the refrigerant pressure is detected by the air conditioner pressure sensor and evaluated by the air conditioning amplifier assembly.
If the refrigerant pressure becomes excessively high, the air conditioning amplifier assembly will regulate or switch off the compressor with magnet clutch based the air conditioner pressure sensor signal. Depending on the refrigerant pressure, a fan setting is determined by the air conditioning amplifier assembly and transferred to the engine control unit via the bus.
The air conditioner pressure sensor evaluates the applied refrigerant pressure in the high pressure line of the refrigerant circuit through a pressure sensitive element. The air conditioner pressure sensor is supplied with a constant electrical current. The actual measurement signal is an output voltage of the sensor with linear dependence upon the refrigerant pressure. The pressure signal is then converted to a digital signal and transmitted to the air conditioning amplifier assembly via the bus.
| *1 | Air Conditioner Pressure Sensor | *2 | 3-pin Plug Connection |
| *a | Illustration shows a representative example. | - | - |