Home › Audio / Visual / Telematics › CELLULAR COMMUNICATION › ETC SYSTEM › from 2021.03
NM3650E _56 Audio / Visual / Telematics _101535 CELLULAR COMMUNICATION _0470569 ETC SYSTEM CO CONTROL F

CELLULAR COMMUNICATION  ETC SYSTEM  CONTROL  ETC CONTROL  


FUNCTION OF MAIN COMPONENTS


Component Function
Toll Collection (ETC) Computer Assembly
·

Transmits wireless radio waves for the ETC (Electronic Toll Collection) system.

·

Displays the operation status of the system by means of the indicator light.




FUNCTION


a.

Initial Processing Function

·

As initial processing, when in ACC ON mode, the indicator light (green light) for the toll collection (ETC) computer assembly turns on for 5 seconds.



b.

Operation Status for the ETC (Electronic Toll Collection) system

·

The operation status for the ETC (Electronic Toll Collection) system can be checked by the indicator light (green/red/blue lights) for the toll collection (ETC) computer assembly turning on/off or flashing.

Toll collection (ETC) computer assembly Status Display Table
Toll collection (ETC) computer assembly Indicator Light Toll collection (ETC) computer assembly Buzzer Toll collection (ETC) computer assembly Operation Status
Green light turns off after flashing (5 seconds) - When the toll collection (ETC) computer assembly is in an available state with the system normal, after initial processing
Green light turns off after coming on (5 seconds) - When the toll collection (ETC) computer assembly is in an unavailable state with the system normal, after initial processing
Red light turns off after coming on (5 seconds) Sounds 1 time (0.5 seconds) When an error occurs with the registration information or radio waves of the toll collection (ETC) computer assembly
Red light turns off after flashing (5 seconds) Sounds 1 time (0.5 seconds) When an irregular process, etc., occurred in the toll collection (ETC) computer assembly
Blue light flashes (2 minutes) - When Bluetooth is in use
Green light turns on (1 time) Sounds 1 time (0.1 seconds) When toll collection completes normally
Red light turns on (1 time) Sounds 3 times (ON 0.1 second, OFF 0.05 seconds) When toll collection does not completes normally