17882
1.INSTALL NO. 2 AIR CLEANER HOSE
Check the sealing ring (1) on the No. 2 air cleaner hose (3) for damage and replace it, if necessary.
Check the sealing ring (2) on the No. 2 air cleaner hose (3) for damage and replace it, if necessary.
Insert and install No. 2 air cleaner hose.
Lock clamp.
The clamp must engage audibly.
Tighten down the T30 bolts.
Connect connectors (2) and lock.
The connector must engage audibly.
Connect connectors (1) and lock.
The connector must engage audibly.
16020
2.CONNECT ELECTRIC WATER PUMP ASSEMBLY
Position the electric water pump assembly.
Insert and install the No. 2 Water Pump bracket sub-assembly.
Tighten nut.
Connect connectors and lock.
17880
3.INSTALL AIR CLEANER HOSE ASSEMBLY