Home › Vehicle Interior › HEATING / AIR CONDITIONING › REFRIGERANT
RM3650E _58 Vehicle Interior _079885 HEATING / AIR CONDITIONING _0387585 REFRIGERANT L

HEATING / AIR CONDITIONING  REFRIGERANT  PRECAUTION  


PRECAUTIONS FOR REFRIGERANT HFC-134a (R134a)


CAUTION:
·

Avoid all contact with liquid or gaseous HFC-134a (R134a). Wear protective goggles and gloves when working on the refrigerant circuit.

·

Although HFC-134a (R134a) at normal temperature is non-toxic, not inflammable and not explosive in air in any mixture ratio, it is still essential to follow various safety precautions.



a.

As a gas, HFC-134a (R134a) is colorless, odorless and heavier than air. If it enters the atmosphere, this may result in an imperceptible danger of asphyxiation or in cardiac palpitations, especially in workshop pits. Ventilate rooms adequately; if necessary, turn on installed extractor systems.


b.

Store filled refrigerant pressure flasks so that they are not subject to direct sunlight or other heat sources (at maximum 45°C (113°F)). Also avoid exposing them to mechanical stress (e.g. by dropping).


c.

Do not weld or solder on to filled heating and air conditioning systems or in rooms into which HFC-134a (R134a) may have escaped. Exposure to flames or high temperatures (below 50°C (122°F)) may give rise to toxic decomposition products (fluorine gas). For this reason, do not smoke either.


d.

In the event of fire, carbon dioxide (CO2), extinguishing powder and a sprayed water jet are deemed to be suitable extinguishing agents. Cool reservoirs at risk with a sprayed water jet (risk of bursting).


e.

If the service valve caps on the service valves are difficult to open, there is a risk of injury from leaking valve inserts (high pressure).


f.

The filled refrigerant circuit of the A/C system is subject to excess pressure. Before carrying out repairs on the A/C system, it is absolutely essential to draw off the refrigerant.

HINT:

Before conducting repairs, check the actual pressure drop on the pressure gauge of the refrigerant recovery unit.



g.

HFC-134a (R134a) must be drawn off, cleaned and returned to the air conditioning using a refrigerant recovery unit following the relevant operating instructions.


h.

For a properly functioning A/C system, it is essential to have the greatest possible levels of cleanliness when working on the A/C system and the longest possible evacuation (at least 30 minutes dehumidification from refrigerant circuit) before each filling of the A/C system.


i.

HFC-134a (R134a) absorbs very small amounts of moisture. Therefore, seal off opened pipes, cooler condenser assembly, evaporator, compressor with pulley assembly and dryer flask immediately with seal plugs.


j.

With replacement parts, the plugs may only be removed immediately before the lines are connected.


k.

Installation note:

i.

After each refilling of an air conditioning, check that service valve caps of the service valves are hand-tight. They serve as additional seals.




PRECAUTIONS FOR REFRIGERANT HFO-1234yf (R1234yf)


CAUTION:
·

Work on the refrigerant circuit may only be carried out by experts.

-

Avoid all contact with liquid or gaseous HFO-1234yf (R1234yf). Wear protective goggles and gloves when working on the refrigerant circuit.


·

Although HFO-1234yf (R1234yf) at normal temperature is non-toxic, non-flammable and not explosive in air in any mixture ratio, it is still essential to follow various safety precautions. At higher temperatures, HFO-1234yf (R1234yf) is inflammable.



a.

As a gas, HFO-1234yf (R1234yf) is colorless, odorless and heavier than air. If it enters the atmosphere, this may result in an imperceptible danger of asphyxiation or in cardiac palpitations, especially in workshop pits. Ventilate rooms adequately; if necessary, turn on installed extractor systems.


b.

Store filled refrigerant pressure flasks so that they are not subject to direct sunlight or other heat sources (at maximum 45°C (113°F)). Also avoid exposing them to mechanical stress (e.g. by dropping).


c.

Do not weld or solder on to filled air conditioning systems or in rooms into which HFO-1234yf (R1234yf) may have leaked. Exposure to flames or high temperatures (below 50°C (122°F)) may give rise to toxic products of decomposition (hydrofluoric acid). For this reason, do not smoke either.


d.

In the event of fire, carbon dioxide (CO2), extinguishing powder and a sprayed water jet are deemed to be suitable extinguishing agents. Cool reservoirs at risk with a sprayed water jet (risk of bursting).


e.

If the service valve caps on the service valves are difficult to open, there is a risk of injury from leaking valve inserts (high pressure).


f.

The filled refrigerant circuit of the A/C system is subject to excess pressure. Before carrying out repairs on the A/C system, it is absolutely essential to draw off the refrigerant.

HINT:

Before conducting repairs, check the actual pressure drop on the pressure gauge of the refrigerant recovery unit.



g.

HFO-1234yf (R1234yf) must be drawn off, cleaned and returned to the A/C system using a refrigerant recovery unit following the relevant operating instructions.


h.

For a properly functioning A/C system, it is essential to have the greatest possible levels of cleanliness when working on the A/C system and the longest possible evacuation (at least 30 minutes dehumidification from refrigerant circuit) before each filling of the A/C system.


i.

HFO-1234yf (R1234yf) easily absorbs moisture. Therefore, seal off opened pipes, cooler condenser assembly, evaporator, compressor with pulley assembly and dryer flask immediately with seal plugs.

i.

If the air conditioning has been completely drained by a leak, accident or repair, the desiccant insert must be replaced as excessive moisture may have entered the system.



j.

With replacement parts, the plugs may only be removed immediately before the lines are connected. In the event of warranty claims, the old parts must be provided with plugs to be able to determine the cause of the damage.


k.

Installation note.

i.

After each refilling of an air conditioning, check that service valve caps of the service valves are hand-tight. They serve as additional seals.




PRECAUTIONS FOR COMPRESSOR OIL


a.

Refrigerant is hygroscopic and must therefore be stored in suitable containers that are sealed airtight.


b.

Compressor oil is non-combustible and non-explosive at normal temperatures. Nevertheless, the following points must be observed.

i.

Do not store in the vicinity of flames, heat sources or strongly oxidizing materials.


ii.

Suitable extinguishants are carbon dioxide (CO2), dry extinguishant and foam.



c.

Protective measures/rules of conduct:

i.

Wear safety goggles.


ii.

Wear oil-resistant protective gloves.


iii.

Do not swallow.


iv.

Do not inhale.


v.

Observe country-specific safety regulations.



d.

First aid measures:

i.

If swallowed:

·

Do not induce vomiting, unless expressly instructed to do so by medical personnel.

·

Do not administer anything to an unconscious person through their mouth. Consult a doctor immediately if larger quantities of this substance are swallowed. Loosen tight-fitting items of clothing (e.g. collar, tie, belt or similar).



ii.

Eye contact:

·

Remove contact lenses if worn. In the event of eye contact, rinse eyes for at least 15 minutes with plenty of water. It is essential to use warm water. Consult a doctor.



iii.

Skin contact:

·

In the event of skin contact, rinse immediately with plenty of water. Remove contaminated clothes and shoes. Wash affected clothes before wearing again. Clean shoes thoroughly before reusing. Consult a doctor.



iv.

After inhalation:

·

If inhaled, take the person affected outside into fresh air immediately and keep them under supervision. Consult a doctor.