Working on fuel system.
Risk of fire! Danger of explosion!
When working on the fuel system, make sure that the workbay is sufficiently ventilated, e.g. using extraction unit.
Tightly seal off open lines and connections; collect any leakage fuel directly at the point of exit.
No fire, sparks, open flames or smoking.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
1. DISCHARGE FUEL SYSTEM PRESSURE
58151
2.REMOVE FRONT NO.1 FLOOR HEAT INSULATOR
77020A
3.REMOVE FUEL SUCTION WITH PUMP AND GAGE TUBE ASSEMBLY
Working on fuel system.
Risk of fire! Danger of explosion!
When working on the fuel system, make sure that the workbay is sufficiently ventilated, e.g. using extraction unit.
Tightly seal off open lines and connections; collect any leakage fuel directly at the point of exit.
No fire, sparks, open flames or smoking.
Unlock and disconnect plug connection (1).
Unlock and disconnect the fuel supply line (2).
Place special tool 2 445 958 on the locking ring (1).
Connect special tool 0 495 554 (33 5 070) with the standard tool (2) and place on special tool 2 445 958.
Plug-in reversible ratchet 1/2 inch
Loosen locking ring (1) counterclockwise and remove.
Lift the flange cover (1) in the direction of the arrow.
To provide a better overview: Schematic diagram with partially hidden components.
Unlock and disconnect plug connection (1).
Unclip the cable holder (2).
Unlock and disconnect quick release (1).
Schematic diagram is for example purposes. Some parts may differ in certain details.
Release the lock (1) in the direction of the arrow upwards.
Press the fuel delivery unit (2) slightly in the direction of the arrow and unthread upwards.