Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P043E    Evaporative Emission System Reference Orifice Clog Up

DTC    P043F    Evaporative Emission System Reference Orifice High Flow

for Preparation Click here


DTC SUMMARY


DTCs
Monitoring Items
Malfunction Detection Conditions
Trouble Areas
Detection Timings
Detection Logics
P043E
Reference orifice clogged
Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine 0.02 inch leak criterion. 0.02 inch leak criterion measured at start and at end of leak check.
If system pressure lower than -4.85 kPa (-36.38 mmHg)*, ECM determines that reference orifice has clogging malfunction.
  1. Canister pump module
  2. Connector/wire harness
    (Canister pump module - ECM)
  3. ECM
  4. Leakage from EVAP system
While ignition switch OFF
2 trips
P043F
Reference orifice high-flow
Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine 0.02 inch leak criterion. 0.02 inch leak criterion generated at start and at end of leak check.
If system pressure higher than -1.06 kPa (-7.95 mmHg)*, ECM determines that reference orifice has high-flow malfunction.
*: The threshold values vary according to the atmospheric pressure measured at the beginning of the EVAP system monitor. The values described in the table above are based on an atmospheric pressure of 100 kPa (750.1 mmHg) (absolute pressure).

HINT:
The reference orifice is located inside the canister pump module.


DESCRIPTION

The circuit description can be found in the EVAP System (Click here).

INSPECTION PROCEDURE

Refer to the EVAP System (Click here).

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned OFF, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

Sequence
Operations
Descriptions
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned OFF.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak criterion measurement
In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak criterion measurement
After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion.
If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
60 seconds
F
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E02


  1. P043E: Reference orifice clogged
    In operation B, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM, using the canister pressure sensor, to determine the 0.02 inch leak criterion. If the pressure is lower than -4.85 kPa (-36.38 mmHg)*, the ECM interprets this as a clog malfunction in the reference orifice, and stops the EVAP (Evaporative Emission) system monitor. The ECM then illuminates the MIL and sets the DTC (2 trip detection logic).
    *: The threshold varies according to the atmospheric pressure measured in operation A. The value described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.


    A106056E07


  2. P043F: Reference orifice high-flow
    In operation B, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM using the canister pressure sensor to determine the 0.02 inch leak criterion. If the pressure is higher than -1.06 kPa (-7.95 mmHg)*, the ECM interprets this as a high-flow malfunction in the reference orifice, and stops the EVAP system monitor. The ECM then illuminates the MIL and sets the DTC (2 trip detection logic).
    *: The threshold varies according to the atmospheric pressure measured in operation A. The value described above is based on a atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.


    A106057E08


MONITOR STRATEGY


Required Sensors/Components
Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever these DTCs not present
None
EVAP key-off monitor runs when all of following conditions met
-
Atmospheric pressure
525 to 825 mmHg (70 to 110 kPa)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
Engine condition
Not running
Fuel tank pressure sensor malfunction (P0450, P0452 and/or P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before IG switch OFF
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. Purge flow
Executed
ECT
4.4° to 35°C (40° to 95°F)
IAT
4.4° to 35°C (40° to 95°F)

Example of restart time 
First time
7 hours
Second time
9 hours and 30 minutes

Key-off monitor sequence is 1 to 8

1. Atmospheric pressure 
Next sequence is run if following condition set
-
Atmospheric pressure change for 10 sec.
Less than 2.25 mmHg (0.3 kPa) for 1 second

2. First 0.02 inch leak criterion 
Next sequence is run if all of following conditions set
Conditions 1, 2 and 3
1. Fuel tank pressure when 4 seconds after 0.02 inch leak criterion measurement began
-7.5 mmHg (-1 kPa) or less
2. 0.02 inch leak criterion
-33.38 to -7.93 mmHg (-4.85 to -1.057 kPa)
3. 0.02 inch leak criterion
Saturated within 55 seconds

3. Vent valve stuck closed check 
Next sequence is run if following condition set
-
Fuel tank pressure change for 10 seconds after vent valve ON (closed)
2.25 mmHg (0.3 kPa) or more

4. Vacuum introduction 
Next sequence is run if both of following condition set
-
1. Vacuum introduction time
12 minutes or less
2. Fuel tank pressure
Fuel tank pressure was standard

5. Purge VSV stuck closed check 
Next sequence is run if following condition set
-
Fuel tank pressure change for 10 seconds after purge VSV ON (open)
2.25 mmHg (0.3 kPa) or more

6. Second 0.02 inch leak criterion measurement 
Next sequence is run if all of following conditions set
Conditions 1, 2, 3 and 4
1. Fuel tank pressure when 4 seconds after 0.02 inch leak criterion measurement began
-7.5 mmHg (-1 kPa) or less
2. 0.02 inch leak criterion
-36.4 to -7.92 mmHg (-4.85 to -1.057 kPa)
3. 0.02 inch leak criterion
Saturated within 55 seconds
4. 0.02 inch leak criterion difference between first and second
5.25 mmHg (0.7 kPa) or less

7. Leak check 
Next sequence is run if following condition set
-
Arrival pressure when vacuum introduced for EVAP system
Leak detection criteria or less

8. Atmospheric pressure 
Monitor is complete if following
-
Atmospheric pressure difference between sequences 1 and 8
2.25 mmHg (0.3 kPa) or less

TYPICAL MALFUNCTION THRESHOLDS


One of following conditions met
-
Fuel tank pressure when 4 seconds after 0.02 inch leak criterion measurement began
More than -7.5 mmHg (-1 kPa)
0.02 inch leak criterion
Less than -36.4 mmHg (-4.85 kPa)
0.02 inch leak criterion
-7.9 mmHg (-1.057 kPa) or more
0.02 inch leak criterion
Not saturated
0.02 inch leak criterion difference between first and second
5.3 mmHg (0.7 kPa) or more
"Saturated" indicates that the EVAP pressure change is less than 0.75 mmHg (0.1 kPa) in 30 seconds.

MONITOR RESULT

Detailed information on Checking Monitor Status (Click here).