DTCs
| Monitoring Items
| Malfunction Detection Conditions
| Trouble Areas
| Detection Timings
| Detection Logic
|
P0441
| Purge VSV (Vacuum Switching Valve) stuck open
| Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check. If stabilized pressure higher than [second 0.02 inch leak criterion x 0.2], ECM determines that purge VSV stuck open
| - Purge VSV
- Connector/wire harness
(Purge VSV - ECM)
- ECM
- Canister pump module
- Leakage from EVAP system
| While ignition Switch OFF
| 2 trip
|
Purge VSV stuck closed
| After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air introduced into EVAP system. 0.02 inch leak criterion measured at start and at end of leak check. If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed
| - Purge VSV
- Connector/wire harness
(Purge VSV - ECM)
- ECM
- Canister pump module
- Leakage from EVAP system
| While ignition Switch OFF
| 2 trip
|
Purge flow
| While engine running, following conditions successively met:
- Negative pressure not created in EVAP system when purge VSV turned ON (open)
- EVAP system pressure change less than 0.5 kPa (3.75 mmHg) when vent valve turned ON (closed)
- Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa (0.75 mmHg)
| - Purge VSV
- Connector/wire harness
(Purge VSV - ECM)
- Leakage from EVAP line
(Purge VSV - Intake manifold)
- ECM
| While engine running
| 2 trip
|
Sequence
| Operation
| Descriptions
| Duration
|
-
| ECM activation
| Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned OFF.
| -
|
A
| Atmospheric pressure measurement
| Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
| 10 seconds
|
B
| First 0.02 inch leak criterion measurement
| In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
| 60 seconds
|
C
| EVAP system pressure measurement
| Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as they will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
| 15 minutes*
|
D
| Purge VSV monitor
| Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal.
| 10 seconds
|
E
| Second 0.02 inch leak criterion measurement
| After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
| 60 seconds
|
F
| Final check
| Atmospheric pressure measured and then monitoring result recorded by ECM.
| -
|
6. Second 0.02 inch leak criterion measurement
Next sequence is run if the following conditions set
| Conditions 1, 2, 3 and 4
|
1. EVAP pressure just after 0.02 inch leak criterion measurement
| -7.5 mmHg (-1 kPa) or less
|
2. 0.02 inch leak criterion
| -36.4 to -7.92 mmHg (-4.85 to -1.057 kPa)
|
3. 0.02 inch leak criterion
| Saturated within 55 seconds
|
4. 0.02 inch leak criterion difference between first and second
| 5.25 mmHg (0.7 kPa) or less
|