Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0455    Evaporative Emission Control System Leak Detected (Gross Leak)

DTC    P0456    Evaporative Emission Control System Leak Detected (Very Small Leak)

for Preparation Click here


DTC SUMMARY


DTC
Monitoring Items
Malfunction Detection Conditions
Trouble Areas
Detection Timings
Detection logic
P0455
EVAP gross leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check.
If stabilized pressure higher than [second 0.02 inch leak criterion x 0.2], ECM determines that EVAP system has large leakage.
  1. Fuel cap (loose)
  2. Leakage from EVAP line
    (Canister - Fuel tank)
  3. Leakage from EVAP line
    (Purge VSV - Canister)
  4. Canister pump module
  5. Leakage from fuel tank
  6. Leakage from canister
While ignition switch OFF
2 trip
P0456
EVAP small leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check.
If stabilized pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system has small leakage.
Same above
While ignition switch OFF
2 trip

DESCRIPTION

The circuit description can be found in the EVAP System (Click here).

INSPECTION PROCEDURE

Refer to the EVAP System (Click here).

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned OFF, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

Sequence
Operations
Descriptions
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned OFF.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak criterion measurement
In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak criterion measurement
After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion.
If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
60 seconds
F
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E02

  1. P0455: EVAP (Evaporative Emission) gross leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second 0.02 inch leak criterion x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leakage, illuminates the MIL and sets the DTC (2 trip detection logic).

  2. P0456: EVAP very small leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than second 0.02 inch leak criterion, the ECM determines that the EVAP system has a small leakage, illuminates the MIL and sets the DTC (2 trip detection logic).


    A106061E07


MONITOR STRATEGY


Required Sensors/Components
Purge VSV and canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever these DTCs not present
None
EVAP key-off monitor runs when all of following conditions met
-
Atmospheric pressure
525 to 825 mmHg (70 to 110 kPa)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
Engine condition
Not running
Fuel tank pressure sensor malfunction (P0450, P0451, P0452 and/or P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before IG switch OFF
Conditions 1 and 2
1. Duration that vehicle driven
5 min. or more
2. Purge flow
Executed
ECT
4.4° to 35°C (40° to 95°F)
IAT
4.4° to 35°C (40° to 95°F)

Key-off monitor sequence 1 to 8

1. Atmospheric pressure 
Next sequence is run if following condition set
-
Atmospheric pressure change for 10 seconds
Less than 2.25 mmHg (0.3 kPa) for 1 seconds

2. First 0.02 inch leak criterion 
Next sequence is run if all of following conditions set
Conditions 1, 2 and 3
1. FTP when 4 seconds after 0.02 inch leak criterion measurement
-7.5 mmHg (-1 kPa) or less
2. 0.02 inch leak criterion
-36.28 to -7.93 mmHg (-4.85 to -1.057 kPa)
3. 0.02 inch leak criterion
Saturated within 55 seconds

3. Vent valve stuck closed check 
Next sequence is run if following condition set
-
Fuel tank pressure change for 10 seconds after vent valve ON (closed)
2.25 mmHg (0.3 kPa) or more

4. Vacuum introduction 
Next sequence is run if both of following conditions set
-
1. Vacuum introduction time
Saturated within 12 minutes
2. Fuel tank pressure
Fuel tank pressure was standard

5. Purge VSV stuck closed check 
Next sequence is run if following condition set
-
Fuel tank pressure change for 10 seconds after purge VSV ON (open)
2.25 mmHg (0.3 kPa) or more

6. Second 0.02 inch leak criterion measurement 
Next sequence is run if all of following conditions set
Conditions 1, 2, 3 and 4
1. Fuel tank pressure when 4 sec. after 0.02 inch leak criterion measurement
-7.5 mmHg (-1 kPa) or less
2. 0.02 inch leak criterion
-36.4 to -7.92 mmHg (-4.85 to -1.057 kPa)
3. 0.02 inch leak criterion
Saturated within 55 seconds
4. 0.02 inch leak criterion difference between first and second
5.25 mmHg (0.7 kPa) or less

7. Leak check 
Next sequence is run if following condition set
-
Fuel tank pressure when vacuum introduction was complete
Second 0.02 inch leak criterion or less

8. Atmospheric pressure 
Monitor is complete if following conditions set
-
Atmospheric pressure difference between sequences 1 and 8
2.25 mmHg (0.3 kPa) or less

TYPICAL MALFUNCTION THRESHOLDS


P0455: EVAP gross leak 
Fuel tank pressure when vacuum introduction complete
Higher than 0.02 inch leak criterion x 0.2

P0456: EVAP small leak 
Fuel tank pressure when vacuum introduction complete
Between 1 and 2
Condition 1
Higher than second 0.02 inch leak criterion
Condition 2
Lower than 0.02 inch leak criterion x 0.2
Atmospheric pressure (absolute pressure)
70 kPa (525 mmHg) or more, and less than 110 kPa (825 mmHg)
"Saturated" indicates that the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) in 30 seconds.

MONITOR RESULT

Detailed information on Checking Monitor Status (Click here).