POWER WINDOW CONTROL SYSTEM > Remote Up / Down Function does not Operate |


| 1.CHECK POWER WINDOW LOCK SWITCH |
![]() |
Turn the window lock switch OFF and operate the master switches assembly passenger side and rear door side switches. Check that the remote UP/DOWN function operates normally.
|
| ||||
| NG | |
| 2.CHECK MANUAL UP/DOWN FUNCTION |
Check that the passenger side and rear door side power window manual UP/DOWN functions operate normally.
|
| ||||
| OK | |
| 3.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
![]() |
Double cab: Inspect the power window regulator master switch assembly.
Remove the power window regulator master switch assembly.
Disconnect the P9 power window regulator master switch connector.
Measure the resistance between the terminals of the connector when the switch is operated.
| Window Lock Switch Condition | Power Window Switch Condition | Tester Condition | Specified Condition |
| OFF (Normal) | UP | P9-1 (E) - P9-15 (PD) P9-7 (B) - P9-18 (PU) | Below 1Ω |
| OFF (Normal) | OFF | P9-1 (E) - P9-18 (PU) P9-1 (E) - P9-15 (PD) | Below 1Ω |
| OFF (Normal) | DOWN | P9-1 (E) - P9-18 (PU) P9-7 (B) - P9-15 (PD) | Below 1Ω |
| ON (Lock) | UP | P9-7 (B) - P9-18 (PU) | Below 1Ω |
| ON (Lock) | OFF | P9-17 (PU) - P9-15 (PD) | Below 1Ω |
| ON (Lock) | DOWN | P9-7 (B) - P9-15 (PD) | Below 1Ω |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Condition | Specified Condition |
| OFF (Normal) | UP | P9-1 (E) - P9-13 (RLD) P9-7 (B) - P9-12 (RLU) | Below 1Ω |
| OFF (Normal) | OFF | P9-1 (E) - P9-12 (RLU) P9-1 (E) - P9-13 (RLD) | Below 1Ω |
| OFF (Normal) | DOWN | P9-1 (E) - P9-12 (RLU) P9-7 (B) - P9-13 (RLD) | Below 1Ω |
| ON (Lock) | UP | P9-7 (B) - P9-12 (RLU) | Below 1Ω |
| ON (Lock) | OFF | P9-12 (RLU) - P9-13 (RLD) | Below 1Ω |
| ON (Lock) | DOWN | P9-7 (B) - P9-13 (RLD) | Below 1Ω |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Condition | Specified Condition |
| OFF (Normal) | UP | P9-1 (E) - P9-16 (RRD) P9-7 (B) - P9-10 (RRU) | Below 1Ω |
| OFF (Normal) | OFF | P9-1 (E) - P9-10 (RRU) P9-1 (E) - P9-16 (RRD) | Below 1Ω |
| OFF (Normal) | DOWN | P9-1 (E) - P9-10 (RRU) P9-7 (B) - P9-16 (RRD) | Below 1Ω |
| ON (Lock) | UP | P9-7 (B) - P9-10 (RRU) | Below 1Ω |
| ON (Lock) | OFF | P9-10 (RRU) - P9-16 (RRD) | Below 1Ω |
| ON (Lock) | DOWN | P9-7 (B) - P9-16 (RRD) | Below 1Ω |
Reconnect the power window regulator master switch connector.
Reinstall the power window regulator master switch assembly.
![]() |
Access cab: Inspect the power window regulator master switch assembly.
Remove the power window regulator master switch assembly.
Disconnect the P9 power window regulator master switch connector.
Measure the resistance between the terminals of the connector when the switch is operated.
| Window Lock Switch Condition | Power Window Switch Condition | Tester Condition | Specified Condition |
| OFF (Normal) | UP | P9-1 (E) - P9-10 (PD) P9-7 (B) - P9-8 (PU) | Below 1Ω |
| OFF (Normal) | OFF | P9-1 (E) - P9-8 (PU) P9-1 (E) - P9-10 (PD) | Below 1Ω |
| OFF (Normal) | DOWN | P9-1 (E) - P9-8 (PU) P9-7 (B) - P9-10 (PD) | Below 1Ω |
| ON (Lock) | UP | P9-9 (B) - P9-8 (PU) | Below 1Ω |
| ON (Lock) | OFF | P9-8 (PU) - P9-10 (PD) | Below 1Ω |
| ON (Lock) | DOWN | P9-9 (B) - P9-10 (PD) | Below 1Ω |
Reconnect the power window regulator master switch connector.
Reinstall the power window regulator master switch assembly.
|
| ||||
| OK | ||
| ||