METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness

for Preparation Click here


WIRING DIAGRAM


B125012E01


INSPECTION PROCEDURE

1.INSPECT LIGHT CONTROL RHEOSTAT


    I045521E01
  1. Disconnect the R4 light control rheostat connector.

  1. Check the voltage and resistance.

    Standard:
    Tester Connection
    Switch Condition
    Specified Condition
    4 (T) - Body ground
    Ignition switch ON, Taillight switch OFF
    Below 1 V
    4 (T) - Body ground
    Ignition switch ON, Taillight switch ON
    10 to 14 V
    1 (IG) - Body ground
    Ignition switch ON
    10 to 14 V
    1 (IG) - Body ground
    Ignition switch OFF
    Below 1 V
    3 (-) - Body ground
    Always
    Below 1 Ω

  1. Reconnect the light control rheostat connector.



NG
REPLACE LIGHT CONTROL RHEOSTAT
OK


2.INSPECT COMBINATION METER ASSEMBLY


    I044513E08
  1. Disconnect the C9 combination meter connector.

  1. Measure the voltage.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    C9-20 - C9-40
    Ignition switch ON
    10 to 14 V

  1. Reconnect the combination meter connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY