MASS AIR FLOW METER > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE V-BANK COVER |
![]() |
Remove the 2 nuts, then remove the V-bank cover.
| 3. REMOVE MASS AIR FLOW METER |
![]() |
Disconnect the connector.
Remove the 2 screws, then remove the mass air flow meter.