Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › KNOCK SENSOR

KNOCK SENSOR > INSPECTION

for Preparation Click here



1. INSPECT KNOCK SENSOR


A093606E03
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard:
      Tester Connection
      Specified Condition
      1 (Ground) - 2 (Output)
      120 to 280 kΩ at 20°C (68°F)

      If the result is not as specified, replace the knock sensor.