Home › TRANSMISSION · A340E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2759    Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

A116548E01
The current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
*: The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A+B) x 100(%).

DTC No.
DTC Detection Condition
Trouble Area
P2759
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving. (1-trip detection logic)
  1. Open or short in shift solenoid valve SLU circuit
  2. Shift solenoid valve SLU
  3. ECM

MONITOR DESCRIPTION

When an open or short is detected in the shift solenoid valve (SLU) circuit, the ECM determines that there is a malfunction. The ECM turns on the MIL and stores this DTC.

MONITOR STRATEGY


Related DTCs
P2759: Shift solenoid valve SLU/Range check
Required sensors/Components
Shift solenoid valve SLU
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present.
None
Solenoid current cut status
Not cut
Battery voltage
11 V or more
CPU commanded duty ratio to SLU
19 % or more

TYPICAL MALFUNCTION THRESHOLDS


Solenoid status (SLU) from IC
Fail (Open or short)
(Output signal duty ratio equal to 100 %)

COMPONENT OPERATING RANGE


Output signal duty ratio
Less than 100 %

WIRING DIAGRAM


C121790E05


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLU)
C121788E04
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 (SLU+) - 7 (SLU-)
    5.1 to 5.5 Ω at 20°C (68°F)
    3 (SLU+) - Body ground
    10 kΩ or higher
    7 (SLU-) - Body ground
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
C095812E41
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    E5-11 (SLU+) - E5-10 (SLU-)
    5.1 to 5.5 Ω at 20°C (68°F)
    E5-11 (SLU+) - Body ground
    10 kΩ or higher
    E5-10 (SLU-) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SLU
D025466E19
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.1 to 5.5 Ω at 20°C (68°F)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLU
OK

REPAIR OR REPLACE TRANSMISSION WIRE