Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0420    Catalyst System Efficiency Below Threshold (Bank 1)

DTC    P0430    Catalyst System Efficiency Below Threshold (Bank 2)

for Preparation Click here


MONITOR DESCRIPTION

The ECM uses sensors mounted in front of and behind the Three-Way Catalytic Converter (TWC) to monitor its efficiency.
The first sensor, the Air-Fuel Ratio (A/F) sensor, sends pre-catalyst information to the ECM. The second sensor, the Heated Oxygen (HO2) sensor, sends post-catalyst information to the ECM.
In order to detect any deterioration in the TWC, the ECM calculates the Oxygen Storage Capacity (OSC) of the TWC. This calculation is based on the voltage output of the HO2 sensor while performing active air- fuel ratio control, rather than the conventional detecting method, which uses the locus ratio.
The OSC value is an indication of the oxygen storage capacity of the TWC. When the vehicle is being driven with a warm engine, active air-fuel ratio control is performed for approximately 15 to 20 seconds. When it is performed, the ECM deliberately sets the air-fuel ratio to lean or rich levels. If a rich-lean cycle of the HO2 sensor is long, the OSC becomes greater. There is a direct correlation between the OSCs of the HO2 sensor and the TWC.
The ECM uses the OSC value to determine the state of the TWC. If any deterioration has occurred, it illuminates the MIL and sets a DTC.

DTC No.
DTC Detection Conditions
Trouble Areas
P0420
OSC value smaller than standard value under active air-fuel ratio control (2 trip detection logic)
  1. Gas leakage from exhaust system
  2. A/F sensor (bank 1 sensor 1)
  3. HO2 sensor (bank 1 sensor 2)
  4. Exhaust manifold (TWC)
P0430
OSC value smaller than standard value under active air-fuel ratio control (2 trip detection logic)
  1. Gas leakage from exhaust system
  2. A/F sensor (bank 2 sensor 1)
  3. HO2 sensor (bank 2 sensor 2)
  4. Exhaust manifold (TWC)

HINT:
  1. Bank 1 refers to the bank that includes cylinder No. 1.
  2. Bank 2 refers to the bank that does not include cylinder No. 1.
  3. Sensor 1 refers to the sensor closest to the engine assembly.
  4. Sensor 2 refers to the sensor farthest away from the engine assembly.


MONITOR STRATEGY


Related DTCs
P0420: Catalyst Deterioration
P0430: Catalyst Deterioration
Required Sensors/Components (Main)
A/F sensor and heated oxygen sensor
Required Sensors/Components (Related)
Intake air temperature sensor, mass air flow meter, crankshaft position sensor and engine coolant temperature sensor
Frequency of Operation
Once per driving cycle
Duration
30 seconds or more
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
P0011 (VVT System 1 - Advance)
P0012 (VVT System 1 - Retard)
P0021 (VVT System 2 - Advance)
P0022 (VVT System 2 - Retard)
P0031, P0032, P0051, P0052 (A/F sensor heater - Sensor 1)
P0037, P0038, P0057, P0058 (HO2 sensor Heater - Sensor 2)
P0100 - P0103 (MAF meter)
P0115 - P0118 (ECT sensor)
P0120 - P0223, P2135 (TP sensor)
P0125 (Insufficient ECT for closed loop)
P0136, P0156 (HO2 Sensor - Sensor 2)
P0171, P0172 (Fuel system)
P0300 - P0306 (Misfire)
P0335 (CKP sensor)
P0340 (CMP sensor)
P0351 - P0356 (Ignitor)
P0500 (VSS)
P2196, P2198 (A/F sensor - rationality)
P2A00, P2A03 (A/F sensor - slow response)
Battery voltage
11 V or more
IAT
-10°C (14°F) or more
Engine coolant temperature sensor
75°C (167°F) or more
Atmospheric pressure coefficient
0.75 or more
Delay time after IDCE ON
Less than 5 seconds
Engine RPM
Less than 3,200 rpm
A/F sensor status
Activated
Fuel system status
Closed loop
Delay time after fuel cut
10 seconds or more
Engine load
10 to 70 %
All of the following conditions are met
Condition 1, 2 and 3
1. Mass air flow rate
5 to 70 g/sec
2. Front catalyst temperature (estimated)
650 to 840°C (1,202 to 1,544°F)
3. Rear catalyst temperature (estimated)
100 to 900°C (212 to 1,652°F)

TYPICAL MALFUNCTION THRESHOLDS


Oxygen Storage Capacity (OSC) of Three-Way Catalytic Converter (TWC)
Less than 0.04 g

MONITOR RESULT

Detailed information on Checking Monitor Status (Click here).

CONDITIONING FOR SENSOR TESTING


HINT:
Perform the operation with the engine speeds and time durations described below prior to checking the waveforms of the A/F and HO2 sensors. This is in order to activate the sensors sufficiently to obtain the appropriate inspection results.

A118003E01

  1. (a) Connect an intelligent tester to the DLC3.
  2. (b) Start the engine and warm it up with all the accessories switched OFF, until the engine coolant temperature stabilizes.
  3. (c) Run the engine at an engine speed of between 2,500 rpm and 3,000 rpm for at least 3 minutes.
  4. (d) While running the engine at 3,000 rpm for 2 seconds and 2,000 rpm for 2 seconds, check the waveforms of the A/F and HO2 sensors using the tester.


HINT:
  1. If either of the voltage outputs of the Air-Fuel Ratio (A/F) or Heated Oxygen (HO2) sensor does not fluctuate, or either of the sensors makes a noise, the sensor may be malfunctioning.
  2. If the voltage outputs of both the sensors remain lean or rich, the air-fuel ratio may be extremely lean or rich. In such cases, perform the following A/F CONTROL using an intelligent tester.
  3. If the Three-Way Catalytic Converter (TWC) has deteriorated, the HO2 sensor (located behind the TWC) voltage output fluctuates up and down frequently, even under normal driving conditions (active air-fuel ratio control is not performed).

A121610E01


CONDITIONING FOR SENSOR TESTING

HINT:
Intelligent tester only:
Malfunctioning areas can be identified by performing the A/F CONTROL function provided in the ACTIVE TEST. The A/F CONTROL function can help to determine whether the Air-Fuel Ratio (A/F) sensor, Heated Oxygen (HO2) sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the A/F CONTROL operation using an intelligent tester.
  1. (1) Connect an intelligent tester to the DLC3.
  2. (2) Start the engine and turn the tester ON.
  3. (3) Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.
  4. (4) Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / A/F CONTROL.
  5. (5) Perform the A/F CONTROL operation with the engine in an idling condition (press the RIGHT or LEFT button to change the fuel injection volume).
  6. (6) Monitor the voltage outputs of the A/F and HO2 sensors (AFS B1S1 and O2S B1S2 or AFS B2S1 and O2S B2S2) displayed on the tester.

HINT:
  1. The A/F CONTROL operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.

    Standard:

    Tester Display
    (Sensor)
    Injection Volumes
    Status
    Voltages
    AFS B1S1 or AFS B2S1
    (A/F)
    +25 %
    Rich
    Less than 3.0
    AFS B1S1 or AFS B2S1
    (A/F)
    -12.5 %
    Lean
    More than 3.35
    O2S B1S2 or O2S B2S2
    (HO2)
    +25 %
    Rich
    More than 0.55
    O2S B1S2 or O2S B2S2
    (HO2)
    -12.5 %
    Lean
    Less than 0.4

NOTICE:
The Air-Fuel Ratio (A/F) sensor has an output delay of a few seconds and the Heated Oxygen (HO2) sensor has a maximum output delay of approximately 20 seconds.


Case
A/F Sensor (Sensor 1)
Output Voltage
HO2 Sensor (Sensor 2)
Output Voltage
Main Suspected
Trouble Areas
1
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
-
Output voltage
More than 3.35 V
Less than 3.0 V
A112626
Output voltage
More than 0.55 V
Less than 0.4 V
A122588
2
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. A/F sensor
  2. A/F sensor heater
  3. A/F sensor circuit
Output voltage
Almost
no reaction
A103185
Output voltage
More than 0.55 V
Less than 0.4 V
A122588
3
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. HO2 sensor
  2. HO2 sensor heater
  3. HO2 sensor circuit
Output voltage
More than 3.35 V
Less than 3.0 V
A112626
Output voltage
Almost
no reaction
A103185
4
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. Injector
  2. Fuel pressure
  3. Gas leakage from exhaust system
(Air-fuel ratio extremely lean or rich)
Output voltage
Almost
no reaction
A103185
Output voltage
Almost
no reaction
A103185
  1. Following the A/F CONTROL procedure enables technicians to check and graph the voltage outputs of both the A/F and HO2 sensors.
  2. To display the graph, select the following menu items on the tester: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / A/F CONTROL / USER DATA / AFS B1S1 and O2S B1S2 or AFS B2S1 and O2S B2S2, and press the YES button and then the ENTER button followed by the F4 button.

INSPECTION PROCEDURE

HINT:
Read freeze frame data using an intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0420 AND/OR P0430)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch ON and turn the tester ON.

  1. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES.

  1. Read DTCs.

    Result:

    Display (DTC Output)
    Proceed To
    P0420 and/or P0430
    A
    P0420 and/or P0430 and other DTCs
    B

    HINT:
    If any DTCs other than P0420 or P0430 are output, troubleshoot those DTCs first.



B
GO TO DTC CHART
A


2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (A/F CONTROL)
  1. Connect an intelligent tester to the DLC3.

  1. Start the engine and turn the tester ON.

  1. Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.

  1. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / A/F CONTROL.

  1. Perform the A/F CONTROL operation with the engine in an idling condition (press the RIGHT or LEFT button to change the fuel injection volume).

  1. Monitor the voltage outputs of the A/F and HO2 sensors (AFS B1S1 and O2S B1S2 or AFS B2S1 and O2S B2S2) displayed on the tester.

    HINT:
    1. The A/F CONTROL operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
    2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.

      Standard:

      Tester Display
      (Sensor)
      Injection Volumes
      Status
      Voltages
      AFS B1S1 or AFS B2S1
      (A/F)
      +25 %
      Rich
      Less than 3.0
      AFS B1S1 or AFS B2S1
      (A/F)
      -12.5 %
      Lean
      More than 3.35
      O2S B1S2 or O2S B2S2
      (HO2)
      +25 %
      Rich
      More than 0.55
      O2S B1S2 or O2S B2S2
      (HO2)
      -12.5 %
      Lean
      Less than 0.4


      Result:

      Status
      AFS B1S1
      or
      AFS B2S1
      Status
      O2S B1S2
      or
      O2S B2S2
      A/F Condition and A/F and
      HO2 Sensors Conditions
      Misfires
      Main Suspected Trouble Areas
      Proceed To
      Lean/Rich
      Lean/Rich
      Normal
      -
      1. Three-Way Catalytic Converter (TWC)
      2. Gas leakage from exhaust system
      A
      Lean
      Lean/Rich
      A/F sensor malfunction
      -
      1. A/F sensor
      B
      Rich
      Lean/Rich
      A/F sensor malfunction
      -
      1. A/F sensor
      Lean/Rich
      Lean
      HO2 sensor malfunction
      -
      1. HO2 sensor
      2. Gas leakage from exhaust system
      C
      Lean/Rich
      Rich
      HO2 sensor malfunction
      -
      1. HO2 sensor
      2. Gas leakage from exhaust system
      Lean
      Lean
      Actual air-fuel ratio lean
      May occur
      1. Extremely rich or lean actual air-fuel ratio
      2. Gas leakage from exhaust system
      A
      Rich
      Rich
      Actual air-fuel ratio rich
      -
      1. Extremely rich or lean actual air-fuel ratio
      2. Gas leakage from exhaust system

      Lean: During A/F CONTROL, the A/F sensor output voltage (AFS) is consistently more than 3.35 V, and the HO2 sensor output voltage (O2S) is consistently less than 0.4 V.
      Rich: During A/F CONTROL, the AFS is consistently less than 3.0 V, and the O2S is consistently more than 0.55 V.
      Lean/Rich: During A/F CONTROL of the ACTIVE TEST, the output voltage of the HO2 sensor alternates correctly.



B
CHECK AND REPLACE AIR FUEL RATIO SENSOR

C
CHECK AND REPLACE HEATED OXYGEN SENSOR, AND CHECK AND REPAIR EXHAUST GAS LEAKAGE
A


3.CHECK FOR EXHAUST GAS LEAKAGE

OK:
No gas leakage.



NG
REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT
OK

REPLACE THREE-WAY CATALYTIC CONVERTER