Home › ENGINE ยท 2TR-FE › COOLING › RADIATOR

RADIATOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. CHECK RADIATOR CAP SUB-ASSEMBLY


Z000570E02
  1. Using a radiator cap tester, slowly pump and check that air comes from the vacuum valve.

    Pumping speed:
    1 push every 3 seconds or more

    NOTICE:
    Push the pump at a constant speed.

    If air does not come from the vacuum valve, replace the radiator cap.

  1. Pump the tester and measure the relief valve opening pressure.

    Standard opening pressure:
    93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)

    Minimum opening pressure:
    78 kPa (0.8 kgf/cm2, 11.4 psi)

    NOTICE:
    The above pumping speed is for the first pumping only (in order to close the vacuum valve). After the first pumping, the pumping speed can be reduced.

    HINT:
    Use the tester's maximum reading as the opening pressure. If the opening pressure is less than the minimum, replace the radiator cap.