Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › OCCUPANT CLASSIFICATION SYSTEM (for Bench Seat Type)

OCCUPANT CLASSIFICATION SYSTEM (for Bench Seat Type) > DATA LIST / ACTIVE TEST

for Preparation Click here


HINT:
By accessing the DATA LIST displayed by the intelligent tester, values of switches and sensors can be checked without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method to shorten diagnostic time.


DATA LIST FOR OCCUPANT CLASSIFICATION ECU


    G035612E02
  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to the ON position.

  3. Following the display on the tester screen, read the DATA LIST.

    HINT:
    The Specified Condition for Zero Point Calibration in the table below must be satisfied when the zero point calibration is performed.


    DATA LIST 
    Item
    Measurement Item/
    Range (Display)
    Normal Condition
    Specified Condition for Zero Point Calibration
    Diagnostic Note
    PASSENGER CLASS
    Passenger classification/
    NG: Data is not determined
    AM50: Adult is seated and seat is in rear position
    AF05: Adult is seated and seat is in front position
    CHILD: Child is seated
    OFF: Vacant
    AF05/AM50/CHILD/OFF
    OFF
    -
    P BUCKLE SW
    Buckle switch (Passenger side)/
    SET: Passenger side seat belt is fastened
    UNSET: Passenger side seat belt is unfastened
    NG: Data is not determined
    UNSET/SET
    UNSET
    -
    SEAT POSITION
    Seat position/
    ON: Seat is in front position
    OFF: Seat is in rear position
    NG: Data is not determined
    ON/OFF
    ON/OFF
    -
    RELATIVE PRESS
    Pressure sensor output/
    Min.: 0
    Max.: 255
    0 to 210
    0 to 2
    -
    FILTERED PRESS
    Filtered pressure sensor output/
    Min.: 0
    Max.: 255
    38 to 240
    38 to 75
    If value outside range of Specified Condition for Zero Point Calibration, check whether any objects placed on seat cushion and that seat cushion fitted correctly.
    THERMISTOR TEMP
    Thermistor temperature output/
    Min.: -40°C (-40°F)
    Max.: 90°C (194°F)
    -40° to 85°C (-40° to185°F)
    3° to 40°C (36° to 104°F)
    If value outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc.
    WEIGHT THRESH
    Weight threshold/
    Min.: 0
    Max.: 255
    36 to 67
    (reference value)
    36 to 67
    (reference value)
    -
    FILTERED TENSION
    Filtered belt tension output/
    Min.: 0
    Max.: 255
    39 to 229
    39 to 64
    (no load)
    -
    EMPTY THRESH
    Empty threshold value from seat factory/
    Min.: 0
    Max.: 255
    38 to 75
    38 to 75
    -
    ALLOW THRESH
    Threshold value for adult passenger or not from seat factory/
    Min.: 0
    Max.: 255
    43 to 64
    (reference value)
    43 to 64
    (reference value)
    -
    #PRESENT CODES
    Number of present trouble codes/
    Min.: 0
    Max.: 255
    0
    0
    -
    #PAST CODES
    Number of past trouble codes/
    Min.: 0
    Max.: 255
    0
    0
    -